Wire Resistance Calculator

A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call

Free wire resistance calculator. Find the resistance of copper or aluminium wire from its length and cross-section or diameter, at any temperature.

Ohms per km
0
Cross-section (mm²)
0

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the wire resistance calculator

  1. Enter the wire length and choose metres or feet. For a circuit, remember that current flows out and back, so the total conductor length is usually twice the cable run.
  2. Enter the cross-sectional area in square millimetres, such as 1.5, 2.5 or 4 mm², or the diameter in millimetres if you don't know the area.
  3. Choose the conductor: copper or aluminium.
  4. Enter the temperature in °C. Resistance rises as wire gets warmer; 20 °C is the standard reference.

The wire resistance calculator shows the total resistance in ohms, the resistance per kilometre, and the cross-section it used.

How the wire resistance calculator works

The resistance of a conductor depends on its material, length and cross-section:

R = ρ × L ÷ A

where R is the resistance in ohms, ρ (rho) the resistivity of the metal in ohm-metres, L the length in metres, and A the cross-sectional area in square metres.

The calculator uses resistivities at 20 °C of about 1.724 × 10⁻⁸ ohm-metres for annealed copper and 2.82 × 10⁻⁸ ohm-metres for aluminium. For other temperatures, it adjusts the resistance:

R(T) = R(20 °C) × (1 + α × (T − 20))

where α is the temperature coefficient: about 0.00393 per °C for copper and 0.00403 per °C for aluminium.

With the default figures, 100 metres of 2.5 mm² copper wire at 20 °C has a resistance of 1.724 × 10⁻⁸ × 100 ÷ 0.0000025 ≈ 0.69 ohms, or about 6.9 ohms per kilometre.

Copper versus aluminium

Aluminium has a higher resistivity than copper, about 1.6 times as much, so an aluminium conductor needs a larger cross-section to match a copper one's resistance. The same 100 metres of 2.5 mm² wire in aluminium would have about 1.13 ohms. Aluminium is lighter and cheaper, which is why it's widely used for overhead power lines and some large supply cables, but it needs suitable connectors and installation methods, because it behaves differently at terminals.

A worked example: an American wire gauge

A run of 14 AWG copper wire is 50 feet long. 14 AWG has a diameter of about 1.628 millimetres.

  1. Area: π × (1.628 ÷ 2)² ≈ 2.08 mm².
  2. Length: 50 feet = 15.24 metres.
  3. Resistance: 1.724 × 10⁻⁸ × 15.24 ÷ 0.00000208 ≈ 0.126 ohms.

Enter 50 feet and a diameter of 1.628 in the wire resistance calculator to check. That's about 2.5 ohms per 1,000 feet, in line with published tables for 14 AWG copper. Our AWG to mm converter gives the diameter for other gauges.

Temperature effects

Copper's resistance rises by roughly 0.4% for every degree Celsius. A cable running at 70 °C, a common maximum conductor temperature for some PVC-insulated cables, has a resistance about 20% higher than at 20 °C. For 100 metres of 2.5 mm² copper, that's about 0.83 ohms instead of 0.69. Enter the expected operating temperature in the wire resistance calculator for a more realistic figure under load.

Why wire resistance matters

  • Voltage drop: current through a wire's resistance causes a voltage drop, V = I × R. Long runs or thin wires can deliver noticeably less voltage at the far end.
  • Power loss: the wire turns power into heat, P = I² × R. Doubling the current quadruples the loss.
  • Safety: excessive heating can damage insulation, which is why cables have current ratings.

For example, 30 metres of 1.5 mm² copper has a resistance of about 0.34 ohms. A circuit with that length of cable in each direction has 0.69 ohms in total, so 10 amps would drop about 6.9 volts. Our voltage drop calculator works through this for circuits directly.

Stranded and solid wire

The calculation uses the conductor's nominal cross-section. Stranded wire, made of many thin wires twisted together, has small gaps between strands, so manufacturers specify its cross-section by the total area of copper rather than the overall diameter. If you measure the diameter of a stranded wire, the wire resistance calculator will overestimate the copper area and underestimate the resistance, so use the area printed on the cable where possible.

AC resistance and skin effect

At mains frequencies, a wire's AC resistance is close to its DC resistance for the cable sizes used in homes. At higher frequencies, current crowds towards the surface of the conductor, an effect called skin effect, which raises the effective resistance. This matters for radio-frequency circuits, switch-mode power supplies and very large conductors. The wire resistance calculator gives the DC resistance.

Who uses a wire resistance calculator

Electricians use it to check voltage drop on long runs. Electronics engineers use it to size wiring and sense resistors. Solar and automotive installers use it for low-voltage DC wiring, where resistance matters most. Students use it to learn about resistivity, and hobbyists use it for heating elements, speaker cables and model railways.

Need more customers from Google?

This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit manages Google Ads for small and mid-size businesses, and only Google Ads. We check your account before we ever get on a call, then fix the structure, the keywords, the tracking and the ads, with month-to-month terms and no long contract. Book a free audit call.

Common mistakes

  • Using the one-way cable length for a circuit that goes out and back.
  • Confusing diameter with area, which gives a very wrong result.
  • Ignoring temperature, which raises resistance under load.
  • Measuring stranded wire's diameter instead of using its rated area.

Low-voltage systems

Wire resistance matters most in low-voltage systems, such as 12 volt vehicles, boats, caravans and solar installations. Because the voltage is low, the current for a given power is high, and a small resistance causes a large proportional drop. For example, a 0.1 ohm cable carrying 20 amps drops 2 volts. On a 230 volt circuit, that's less than 1% of the voltage, but on a 12 volt circuit it's about 17%, enough to dim lights and stop pumps or fridges working properly. Use the wire resistance calculator with the full out-and-back length to check, and choose a larger cable if the drop is more than your system allows. Many guides for low-voltage DC suggest keeping voltage drop to a few per cent for critical loads.

Speaker cables

Speaker cables also have resistance in series with the speaker. A long, thin cable adds resistance that wastes amplifier power and can slightly change the sound by reducing the amplifier's control over the speaker. A common guideline is to keep the cable's total resistance to a small fraction, often around 5%, of the speaker's impedance. For an 8 ohm speaker, that's about 0.4 ohms for the round trip. The wire resistance calculator shows how long a run of a given size meets that target.

Heating elements

Resistance wire, such as nichrome, is designed to have a high resistivity so it heats up when current flows. The same R = ρ × L ÷ A formula applies, with the alloy's resistivity, which is much higher than copper's. The wire resistance calculator covers only copper and aluminium, but the method is the same for any metal if you know its resistivity.

Measuring resistance

A standard multimeter can struggle to measure very low resistances accurately, because the resistance of its test leads and contacts is similar to the wire being measured. For low values, a four-wire (Kelvin) measurement, using separate pairs of leads for current and voltage, gives much more accurate results. A simpler check is to pass a known current through the wire and measure the voltage across it: R = V ÷ I. Compare the result with the wire resistance calculator to check cable quality or spot a poor connection.

Connections and terminals

In real circuits, connections often add more resistance than the wire itself. Loose terminals, corroded contacts and poorly crimped lugs can each add resistance and heat up under load, sometimes dangerously. Tight, clean, properly crimped or soldered connections keep the total resistance close to the wire's own figure from the wire resistance calculator.

Ageing cables

Over many years, oxidation at joints, damaged strands and repeated heating can raise a cable's effective resistance. If a measured value is well above the wire resistance calculator's figure, inspect the cable and its connections.

Sources and further reading

Frequently asked questions

How do I calculate wire resistance?

R = resistivity × length ÷ area. Copper's resistivity is about 1.724 × 10⁻⁸ ohm-metres at 20 °C.

What is the resistance of 2.5 mm² copper wire?

About 6.9 ohms per kilometre at 20 °C, or 0.69 ohms per 100 metres.

Does temperature change resistance?

Yes. Copper's resistance rises about 0.4% per °C.

Is aluminium wire more resistive?

Yes, about 1.6 times copper for the same size.

Should I double the cable length?

For a circuit, yes: current flows out and back.

Is the wire resistance calculator free?

Yes. It's free, needs no sign-up, and works in your browser.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep