Voltage Drop Calculator

A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call

Free voltage drop calculator for copper and aluminium cable. Enter voltage, current, length and wire size (AWG or mm²) to see the drop and percentage.

An estimate at 20 °C. Cable sizing must follow your local wiring regulations; ask a qualified electrician.

Voltage drop
0
Voltage at the load
0
Conductor resistance (one way)
0

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the voltage drop calculator

  1. Enter the supply voltage, for example 120 V, 230 V, 240 V or 12 V.
  2. Enter the current the circuit will carry, in amps.
  3. Enter the one-way length of the cable from the supply to the load, in feet or metres.
  4. Choose the wire size, as an AWG gauge or in mm².
  5. Choose copper or aluminium, and single-phase/DC or three-phase.

The voltage drop calculator shows the voltage lost in the cable, the drop as a percentage of the supply, the voltage at the load, the total resistance of the conductors and their cross-sectional area.

What is voltage drop?

Every wire has some resistance. When current flows through it, part of the supply voltage is used up pushing the current along the wire, and that part never reaches the load. This loss is called voltage drop. On short runs with suitably sized cable, it's tiny. On long runs, with high currents or undersized wire, it can be large enough to make lights dim, motors run hot and struggle to start, and electronics misbehave.

Voltage drop also wastes energy as heat in the cable. The power lost is the current multiplied by the voltage drop.

The voltage drop formula

For single-phase AC and DC circuits, the current flows out along one conductor and back along the other, so the total length of conductor is twice the one-way length:

Voltage drop = 2 × length × current × resistivity ÷ cross-sectional area

For balanced three-phase circuits, the line-to-line voltage drop uses √3 instead of 2:

Voltage drop = √3 × length × current × resistivity ÷ cross-sectional area

The voltage drop calculator uses a resistivity of 1.724 × 10⁻⁸ ohm-metres for copper and 2.82 × 10⁻⁸ ohm-metres for aluminium, both at 20 °C, and calculates resistance from the wire's area. It ignores reactance, which is small for most building wiring and small cables but becomes significant for large cables carrying AC.

A worked example in feet and AWG

A 120 V circuit runs 100 feet to a load drawing 15 A, using 12 AWG copper wire.

  1. Resistance of 12 AWG copper: about 1.588 ohms per 1,000 feet.
  2. Total conductor length: 2 × 100 = 200 feet, so the resistance is about 0.318 ohms.
  3. Voltage drop: 15 × 0.318 ≈ 4.76 V.
  4. Percentage: 4.76 ÷ 120 ≈ 3.97%.
  5. Voltage at the load: about 115.2 V.

Moving up to 10 AWG reduces the drop to about 3.0 V, or 2.5%. Enter these figures in the voltage drop calculator to compare the two sizes.

A worked example in metres and mm²

A 230 V circuit runs 30 metres to a load drawing 16 A, using 2.5 mm² copper cable.

  1. Total resistance: 2 × 30 × 1.724 × 10⁻⁸ ÷ (2.5 × 10⁻⁶) ≈ 0.207 ohms.
  2. Voltage drop: 16 × 0.207 ≈ 6.62 V.
  3. Percentage: about 2.88%.

A three-phase example: 400 V line to line, 32 A, 50 metres of 6 mm² copper gives a drop of about 7.96 V, or 1.99%.

How much voltage drop is acceptable?

Limits depend on the country, the type of circuit and the code that applies:

  • United States: the National Electrical Code includes informational notes, which are recommendations rather than requirements, suggesting a maximum of 3% voltage drop on a branch circuit and 5% in total for the feeder and branch circuit together. Some installations, such as fire pumps, have mandatory limits.
  • United Kingdom: BS 7671, the IET Wiring Regulations, gives maximum values for installations supplied from the public low-voltage network, commonly 3% for lighting and 5% for other uses.
  • Other countries: have their own wiring rules with similar limits.

Low-voltage DC systems, such as 12 V solar, vehicle and boat wiring, are especially sensitive, because a drop of 1 V is more than 8% of 12 V. Many installers aim for 3% or less on these systems, and less still for critical loads.

Always follow the code that applies to your installation and consult a qualified electrician for building wiring. The voltage drop calculator is a planning aid, not a substitute for code compliance.

Ways to reduce voltage drop

  • Use a thicker cable. Doubling the cross-sectional area halves the drop.
  • Shorten the run, for example by moving the supply or load closer.
  • Use a higher voltage. For the same power, doubling the voltage halves the current, which quarters the percentage drop.
  • Use copper instead of aluminium, or a larger aluminium cable.
  • Split the load across more than one circuit.

Copper versus aluminium

Aluminium conductors are lighter and cheaper than copper, and are widely used for service entrances, feeders and overhead lines. But aluminium has about 1.6 times the resistivity of copper, so an aluminium cable needs to be larger to carry the same current with the same voltage drop. Aluminium also needs connectors and terminals rated for it, because it expands differently and forms an oxide layer that can cause poor connections if not handled properly.

Who uses a voltage drop calculator

Electricians use it to size cables for long runs to garages, outbuildings, pumps and gates. Solar and battery installers use it to size DC cables between panels, controllers, batteries and inverters. Electrical engineers use it in design calculations. RV, boat and vehicle owners use it when adding lights, fridges and inverters. Landscape lighting installers use it to make sure the lights at the end of a run aren't too dim.

Get the next job from Google

Homeowners search Google when something breaks. Search ads put a local trade business at the top of those searches. DeepRit manages Google Ads for small and mid-size businesses, and only Google Ads. We check your account before we ever get on a call, then fix the structure, the keywords, the tracking and the ads, with month-to-month terms and no long contract. Book a free audit call.

Temperature effects

Copper's resistance increases by about 0.39% for each degree Celsius. A cable running at 75 °C, a typical maximum for many insulation types, has roughly 21% more resistance than at 20 °C, so its voltage drop is about 21% higher than the voltage drop calculator shows. For cables that run near their maximum current, or in hot locations such as attics and conduits in the sun, allow extra margin.

Voltage drop and ampacity are separate checks

A cable must satisfy two separate requirements: it must carry the current without overheating (ampacity), and it must deliver enough voltage to the load (voltage drop). On short runs, ampacity usually decides the size. On long runs, voltage drop often does, and you may need a cable much larger than the ampacity tables require. Check both. The AWG to mm converter helps when moving between AWG and metric sizes.

Motor starting

Motors draw several times their running current for a moment when they start. During that inrush, voltage drop is much larger, and if it's too large, the motor may struggle to start, or lights on the same circuit may flicker. For motor circuits on long runs, check the voltage drop at the starting current as well as the running current, using the motor's locked-rotor or starting current from its nameplate or datasheet.

Common mistakes

  • Entering the round-trip length instead of the one-way length, which doubles the result.
  • Sizing cable for ampacity only on long runs.
  • Forgetting that low-voltage DC systems are much more sensitive to voltage drop.
  • Ignoring higher resistance at operating temperature.

12 V systems: an example

Low-voltage DC wiring shows why voltage drop matters so much. Suppose a 12 V fridge in a camper van draws 5 A and sits 6 metres from the battery. With 2.5 mm² copper cable, the round trip is 12 metres, the resistance is about 0.083 ohms, and the drop is about 0.41 V, or 3.4%. Moving up to 4 mm² cuts the drop to about 0.26 V, or 2.2%. That's the same physics as in a house, but because the supply voltage is ten or twenty times lower, a drop of a fraction of a volt becomes a significant percentage. Fridges, pumps and inverters can shut down or work poorly when their voltage sags, so use the voltage drop calculator for every circuit in a vehicle, boat or off-grid system, and size inverter and battery cables generously.

Checking an existing circuit

If lights dim or equipment struggles at the far end of a long run, you can compare the voltage drop calculator's estimate with a measurement. Measure the voltage at the supply and at the load while the load is running; the difference is the actual drop. If the measured drop is much larger than the voltage drop calculator predicts, look for a loose or corroded connection, which adds resistance in one spot and can overheat. Any work on mains wiring should be done by a qualified electrician.

Sources and further reading

Frequently asked questions

How is voltage drop calculated?

For single-phase or DC: 2 × length × current × resistivity ÷ area. For three-phase, use √3 instead of 2.

What is an acceptable voltage drop?

Commonly 3% for a branch circuit and 5% in total, but follow the code that applies to your installation.

Should I enter the one-way or round-trip length?

The one-way length. The calculator accounts for the return conductor.

How do I reduce voltage drop?

Use a thicker cable, shorten the run, raise the voltage, or use copper instead of aluminium.

Does the calculator include reactance?

No. It uses resistance only, which is accurate for most small and medium cables.

Is the voltage drop calculator free?

Yes. It's free, needs no sign-up, and works in your browser.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep