PCB Trace Width Calculator (IPC-2221)

A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call

Free PCB trace width calculator using IPC-2221. Find the minimum trace width for a current, temperature rise and copper weight, outer or inner layers.

Width (mm)
0
Cross-section (mil²)
0
Copper thickness (mil)
0

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the PCB trace width calculator

  1. Enter the current the trace must carry, in amps.
  2. Enter the allowed temperature rise in degrees Celsius: how much hotter than its surroundings the trace may get. 10 °C is a common, conservative choice.
  3. Enter the copper weight in ounces per square foot. 1 oz copper, about 35 micrometres thick, is the most common; 2 oz is used for higher currents.
  4. Choose the layer: external (top or bottom) or internal (inside a multilayer board).

The PCB trace width calculator shows the minimum trace width in mils and millimetres, along with the cross-sectional area and copper thickness it used.

How the PCB trace width calculator works

The calculator uses the widely used formula from the IPC-2221 standard, which relates current to the trace's cross-section and temperature rise:

I = k × ΔT^0.44 × A^0.725

where I is the current in amps, ΔT the temperature rise in °C, A the cross-sectional area in square mils, and k a constant: 0.048 for external layers and 0.024 for internal layers.

Rearranged to find the area:

A = (I ÷ (k × ΔT^0.44))^(1 ÷ 0.725)

Width = A ÷ (copper thickness in mils)

The copper thickness is taken as about 1.378 mils per ounce of copper.

With the default figures, 2 amps with a 10 °C rise on 1 oz copper on an external layer needs a cross-section of about 42.4 square mils, which divided by 1.378 mils of thickness gives a width of about 30.8 mils, or about 0.78 millimetres. The same current on an internal layer needs about 80 mils, or about 2.03 millimetres.

Why internal traces need to be wider

External traces lose heat to the surrounding air by convection and radiation. Internal traces are buried inside the board's insulating material, which conducts heat away less effectively, so they run hotter for the same current. The IPC-2221 formula reflects this by halving the constant k for internal layers, so internal traces need to be more than twice as wide for the same current and temperature rise.

Typical widths

For 1 oz copper with a 10 °C rise on an external layer, the PCB trace width calculator gives:

Current Width (mils) Width (mm)
0.5 A about 4.5 about 0.12
1 A about 11.8 about 0.30
2 A about 30.8 about 0.78
3 A about 53.8 about 1.37

Notice that width doesn't rise in direct proportion to current: doubling the current from 1 to 2 amps more than doubles the width needed.

A worked example: a motor driver

A motor driver board needs to carry 5 amps on an external layer of 2 oz copper, and a 20 °C rise is acceptable for this design.

  1. Area: (5 ÷ (0.048 × 20^0.44))^(1 ÷ 0.725) ≈ 98.5 square mils.
  2. Thickness: 2 × 1.378 = 2.756 mils.
  3. Width: 98.5 ÷ 2.756 ≈ 35.7 mils, about 0.91 millimetres.

Enter 5, 20, 2 and external in the PCB trace width calculator to check. Many designers would round up and add margin for manufacturing tolerances and nearby heat sources.

Choosing a temperature rise

The temperature rise is a design choice. A lower rise keeps the board cooler and more reliable but needs wider traces. A 10 °C rise is a common default, while 20 °C or more may be acceptable in some designs, depending on the board material, ambient temperature, nearby components and any standards the product must meet. Remember that the trace temperature adds to the ambient temperature and heat from components: a trace with a 20 °C rise in a 50 °C enclosure reaches 70 °C.

Limits of the formula

The IPC-2221 formula is based on older test data and is widely regarded as conservative for many situations, but it doesn't account for everything. Wide copper pours, nearby planes, vias, thermal relief, board thickness and air flow all affect real temperatures. The newer IPC-2152 standard provides more detailed charts that consider some of these factors. For high-current, high-reliability or compact designs, use the PCB trace width calculator as a starting point and confirm with more detailed analysis, thermal simulation or testing.

Copper weights

Copper weight describes the mass of copper spread over one square foot of board:

  • 0.5 oz: about 17.5 micrometres, often used on fine-pitch inner layers.
  • 1 oz: about 35 micrometres, the most common.
  • 2 oz: about 70 micrometres, for higher currents.
  • 3 oz and above: heavy copper, for power electronics.

Heavier copper carries more current in a narrower trace, but it costs more and makes fine features harder to etch. Plating on outer layers can also add thickness, so ask your board manufacturer for their finished thickness.

Who uses a PCB trace width calculator

Electronics engineers use it to lay out power traces on circuit boards. PCB designers use it to set design rules for different nets. Hobbyists use it when designing their own boards for power supplies, motor drivers and LED projects. Students use it in electronics design courses, and reviewers use it to check that a layout can handle its currents.

Need more customers from Google?

This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit manages Google Ads for small and mid-size businesses, and only Google Ads. We check your account before we ever get on a call, then fix the structure, the keywords, the tracking and the ads, with month-to-month terms and no long contract. Book a free audit call.

Voltage drop on traces

Width also affects resistance and voltage drop. A long, narrow trace carrying a few amps can lose a noticeable voltage, which matters for power rails feeding sensitive components. Our wire resistance calculator estimates the resistance of a conductor from its cross-section and length; for a trace, the cross-section is the width times the copper thickness. For power rails, many designers use wide pours or planes rather than single traces.

Common mistakes

  • Using external widths for internal layers.
  • Forgetting the copper weight, especially on inner layers that may be thinner.
  • Ignoring ambient temperature and heat from nearby components.
  • Treating the formula as exact for compact, high-current designs.

Vias for high currents

When a high-current trace changes layer, it passes through vias, plated holes connecting the layers. A single small via may not carry as much current as the trace it connects, because its copper plating is thin. Designers often use several vias in parallel for power connections, spreading the current between them. The board manufacturer's plating thickness and via sizes determine each via's capacity, and many PCB design tools and fabricators publish guidance. Don't let a well-sized trace from the PCB trace width calculator be let down by a single via.

Wide pours and planes

For the highest currents, many designs use copper pours or whole planes instead of traces. A ground or power plane offers a very wide conductor with low resistance and good heat spreading. Planes also help with signal integrity and electromagnetic compatibility. Where a narrow trace must connect to a pour, such as at a component pad, the narrowest point limits the current, so check the width there as well.

Thermal relief and pads

Pads connected to large copper areas are often given thermal relief, a few narrow spokes instead of a solid connection, so they're easier to solder. Those spokes carry the full current, so for high-current pads, check that the spokes' total width is enough, or use a solid connection and allow for the extra heat needed when soldering.

Manufacturing limits

Board manufacturers have minimum trace widths and spacings, often around 4 to 6 mils for standard processes, and wider for heavy copper. Very wide traces are easy to make, but they use board space. Spacing between traces is set by voltage and safety requirements, not current, and high-voltage designs need extra clearance and creepage distance under standards that apply to the product. Check your fabricator's capabilities before finalising widths from the PCB trace width calculator.

Converting units

PCB dimensions are often given in mils, thousandths of an inch. One mil is 0.0254 millimetres, so 10 mils is 0.254 mm, and 1 millimetre is about 39.4 mils. Many design tools let you work in either. The PCB trace width calculator shows both, so you can enter design rules in whichever unit your software uses.

Checking a finished board

A thermal camera or a thermocouple taped to a trace can confirm the temperature rise under full load. Comparing the measurement with the design target shows whether the trace, and the board as a whole, has enough margin.

Sources and further reading

  • Printed circuit board on Wikipedia: board construction, layers and copper weights.
  • Ampacity on Wikipedia: the current a conductor can carry before overheating.
  • IPC (electronics) on Wikipedia: the industry association behind the IPC-2221 and IPC-2152 standards.

Frequently asked questions

How wide should a PCB trace be for 2 amps?

About 31 mils (0.78 mm) on an external 1 oz layer with a 10 °C rise.

What formula does the calculator use?

The IPC-2221 formula: I = k × ΔT^0.44 × A^0.725, with k = 0.048 external and 0.024 internal.

Why are internal traces wider?

They're surrounded by insulation, so they shed heat less easily.

What copper weight should I use?

1 oz is standard; 2 oz or more suits higher currents.

Is IPC-2221 accurate?

It's a widely used, generally conservative estimate; IPC-2152 gives more detailed guidance.

Is the PCB trace width calculator free?

Yes. It's free, needs no sign-up, and works in your browser.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep