UPS Runtime Calculator
A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call
Free UPS runtime calculator. Estimate how long a UPS battery runs your computer or router from battery voltage, amp-hours, efficiency and load in watts.
- Battery energy (Wh)
- 0
- Hours
- 0
Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.
How to use the UPS runtime calculator
- Enter the battery voltage, usually 12 V for each battery in small and medium UPS units. It's printed on the battery label.
- Enter the battery capacity in amp-hours (Ah), also on the label, such as 7 Ah or 9 Ah.
- Enter the number of batteries in the UPS. Many desktop units have one; larger ones have two or more.
- Enter the load in watts: the total power drawn by everything plugged into the UPS's battery-backed outlets.
- Enter the inverter efficiency, often around 85% to 95%.
- Enter the usable capacity as a percentage, to allow for ageing or to avoid deep discharge.
The UPS runtime calculator shows the estimated runtime in minutes and hours, and the battery energy in watt-hours.
The result is an estimate. Real runtime depends on battery age, temperature and especially the load, as explained below, so check the UPS manufacturer's runtime chart for your model.
What is a UPS?
An uninterruptible power supply (UPS) keeps equipment running when the mains power fails. It contains batteries and an inverter that converts the batteries' DC power to AC. When the power goes out, the UPS switches to battery, usually in a few milliseconds or less, so computers, routers and other devices keep working. Its main jobs are to ride through short outages and to give you time to save work and shut down safely during longer ones.
How the UPS runtime calculator works
Battery energy (Wh) = voltage × amp-hours × number of batteries
Runtime (hours) = battery energy × efficiency × usable share ÷ load
With the default figures, two 12 V, 9 Ah batteries supplying a 200 W load through a 90% efficient inverter:
- Battery energy: 12 × 9 × 2 = 216 Wh.
- Usable energy: 216 × 0.9 = 194.4 Wh.
- Runtime: 194.4 ÷ 200 = 0.97 hours, about 58 minutes.
Why real runtime is often shorter
The simple calculation assumes the battery delivers its full rated capacity at any load. Lead-acid batteries, which most UPS units use, don't. Their amp-hour rating is usually measured over a long discharge, often 20 hours. When discharged quickly, as in a UPS supplying a heavy load, they deliver noticeably less, an effect described by Peukert's law. At the high loads typical of a UPS, a small lead-acid battery might deliver well under its rated capacity. As a result:
- At light loads, real runtime is often close to the calculated figure.
- At heavy loads, near the UPS's maximum, real runtime can be much shorter.
Lead-acid batteries also lose capacity as they age, typically over three to five years in a UPS, and deliver less in the cold. Lithium-ion UPS batteries are less affected by high discharge rates and usually last longer.
To allow for these effects in the UPS runtime calculator, lower the usable capacity, for example to 60% or 70% for a heavily loaded or older lead-acid battery.
Measuring your load
The most accurate way to know your load is to measure it. Many UPS units display the load in watts or as a percentage of their capacity. A plug-in power meter between the wall and your equipment also shows it. Nameplate ratings on power supplies are maximums, so real consumption is usually much lower: a desktop computer with a 500 W power supply might draw 60 to 150 W in normal use.
Typical loads are roughly:
- Router and modem: 10 to 30 W.
- Laptop: 20 to 90 W.
- Desktop PC with monitor: 100 to 300 W, more for gaming PCs.
- Small NAS: 20 to 60 W.
A worked example: keeping the internet on
You want to keep a router, a modem and a network switch running, drawing 30 W in total, from a UPS with one 12 V, 100 Ah battery, an 85% efficient inverter, and only half the battery's capacity used to protect its life.
- Battery energy: 12 × 100 = 1,200 Wh.
- Usable: 1,200 × 0.85 × 0.5 = 510 Wh.
- Runtime: 510 ÷ 30 = 17 hours.
At 300 W, the same setup would last 510 ÷ 300 = 1.7 hours, about 102 minutes. Enter both loads in the UPS runtime calculator to compare. Light loads give long runtimes, which is why a small UPS can keep a router going for hours but a gaming PC only for minutes.
VA and watts
UPS units are often rated in volt-amperes (VA) and watts. VA is the apparent power, and watts the real power; the watt rating is usually lower, often around 60% to 90% of the VA figure. Make sure your load in watts is within the UPS's watt rating, ideally with some headroom, and use watts in the UPS runtime calculator.
Who uses a UPS runtime calculator
Home office workers use it to keep computers and internet running through power cuts. IT staff use it to size UPS systems for servers and network equipment. Small business owners use it to protect point-of-sale systems and security cameras. Gamers and streamers use it to protect equipment, and anyone in an area with frequent outages uses it to plan backup power.
Need more customers from Google?
This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit is a Google Ads agency that does PPC and nothing else: we build the campaigns, block the searches that waste money, write the ads, set up conversion tracking and send you a short report every week. Request a free PPC audit and we will show you, in dollars, what we would fix first.
Extending runtime
To get more runtime, you can reduce the load, for example by keeping only essential equipment on the battery outlets, use a UPS that accepts external battery packs, or choose a larger battery. Many UPS units can also signal computers to shut down automatically when the battery runs low, using software connected by USB or the network, which protects data during long outages when nobody is there.
Battery care and replacement
UPS batteries wear out. Many UPS units run a self-test and warn when the battery needs replacing. Keeping the UPS in a cool, ventilated place extends battery life, since heat shortens it significantly. When replacing batteries, use the type and capacity the manufacturer specifies, and recycle the old ones properly.
Common mistakes
- Using the power supply's maximum rating instead of measured load.
- Assuming rated capacity at high loads for lead-acid batteries.
- Confusing VA with watts.
- Forgetting battery ageing, which steadily reduces runtime.
Types of UPS
There are three main types of UPS, which differ in how they handle power:
- Standby (offline) UPS: passes mains power straight through and switches to battery when the power fails. It's simple and inexpensive, common for home computers.
- Line-interactive UPS: also corrects small voltage changes without using the battery, using a transformer. It's popular for small offices and network equipment.
- Online (double-conversion) UPS: continuously converts power to DC and back to AC, so the equipment is always running from the inverter. It gives the cleanest power and no switching gap, and is used for servers and sensitive equipment, though it's less efficient.
The runtime calculation works the same way for all three, but online units use some power continuously, which slightly reduces efficiency.
Sizing a UPS
To choose a UPS, first add up the measured load in watts of everything that needs protecting. Then choose a UPS whose watt rating exceeds that load with a comfortable margin, often around 20% to 25%, so it isn't running at its limit. Finally, use the UPS runtime calculator, or the manufacturer's runtime chart, to check that it gives enough runtime for your needs. If it doesn't, consider a model with more battery capacity or support for external battery packs, rather than simply a higher power rating.
Pure sine wave output
Some lower-cost UPS units produce a stepped, or simulated, sine wave on battery. Many modern computer power supplies, especially those with active power factor correction, work best with a pure sine wave and can misbehave or shut down on a stepped waveform. If you have such equipment, choose a UPS with pure sine wave output.
How long do you actually need?
For most home and small office uses, the goal is to ride through short outages, which are often just seconds or minutes, and to give enough time to save work and shut down during longer ones. Five to fifteen minutes is often plenty for a computer. For network equipment that keeps phones and internet running, longer runtimes are useful, which is why many people put only their router and modem on a separate, small UPS: the low load gives hours of runtime from a modest battery, as the UPS runtime calculator shows.
Sources and further reading
- Uninterruptible power supply on Wikipedia: UPS types, ratings and batteries.
- Peukert's law on Wikipedia: why batteries deliver less capacity at high discharge rates.
- Lead–acid battery on Wikipedia: the battery type used in most UPS units.
Frequently asked questions
How do I calculate UPS runtime?
Multiply battery volts × amp-hours × number of batteries × efficiency, then divide by the load in watts.
How long will a UPS with two 12 V 9 Ah batteries run 200 W?
About 58 minutes in theory, often less in practice for lead-acid batteries.
Why is my real runtime shorter?
Lead-acid batteries deliver less at high loads and lose capacity as they age.
What load should I enter?
The measured load in watts, not the power supply's maximum rating.
What's the difference between VA and watts?
VA is apparent power; watts are real power. Use watts for runtime.
Is the UPS runtime calculator free?
Yes. It's free, needs no sign-up, and works in your browser.