Solar Battery Bank Calculator
A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call
Free solar battery bank calculator. Size an off-grid battery bank in kWh and amp-hours from daily use, days of autonomy and depth of discharge.
- Capacity (kWh)
- 0
- Capacity (Wh)
- 0
Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.
How to use the solar battery bank calculator
- Enter your daily energy use in watt-hours (Wh). Add up each device's power in watts multiplied by the hours it runs each day; a 100 watt device running for 5 hours uses 500 Wh.
- Enter the days of autonomy: how many days the battery bank should power your loads without any solar charging, for cloudy spells.
- Enter the battery bank voltage, commonly 12, 24 or 48 volts.
- Enter the usable depth of discharge (DoD): how much of the battery's capacity you plan to use. Lithium iron phosphate batteries are often used to about 80% or more; lead-acid batteries are usually limited to about 50% to protect their life.
- Enter the inverter efficiency, often around 90%, to allow for energy lost converting DC to AC.
The solar battery bank calculator shows the battery capacity you need in amp-hours (Ah) at your bank voltage, and in kilowatt-hours (kWh).
How the solar battery bank calculator works
Energy needed (Wh) = daily use × days of autonomy ÷ depth of discharge ÷ inverter efficiency
Capacity (Ah) = energy needed ÷ bank voltage
With the default figures, 2,000 Wh a day for 2 days, with 80% usable depth of discharge and a 90% efficient inverter, needs 2,000 × 2 ÷ 0.8 ÷ 0.9 ≈ 5,556 Wh, or about 5.56 kWh. At 24 volts, that's 5,556 ÷ 24 ≈ 231.5 Ah.
Why depth of discharge matters
Batteries aren't usually drained completely. Regularly discharging a battery deeply shortens its life, and the effect is much stronger for lead-acid batteries than for lithium batteries. Sizing the bank so you only use part of its capacity means a bigger bank, but it lasts more years:
- Flooded and sealed lead-acid batteries are commonly sized for about 50% depth of discharge in daily cycling.
- Lithium iron phosphate (LiFePO4) batteries are often used to about 80% to 90% depth of discharge, depending on the manufacturer's guidance and warranty.
Check the battery datasheet for its rated cycle life at different depths of discharge, and use that figure in the solar battery bank calculator.
A worked example: an off-grid cabin
A small cabin uses about 1,200 Wh a day: lights, a small fridge, a laptop and a water pump. You want 3 days of autonomy at 12 volts, with a 90% efficient inverter.
With lead-acid batteries at 50% DoD:
- Energy: 1,200 × 3 ÷ 0.5 ÷ 0.9 = 8,000 Wh (8 kWh).
- Capacity: 8,000 ÷ 12 ≈ 667 Ah at 12 volts.
With lithium iron phosphate batteries at 80% DoD:
- Energy: 1,200 × 3 ÷ 0.8 ÷ 0.9 = 5,000 Wh (5 kWh).
- Capacity: 5,000 ÷ 12 ≈ 417 Ah at 12 volts.
Enter these figures in the solar battery bank calculator to compare. A 12 volt bank of that size carries high currents, so many designers would choose a 24 or 48 volt bank for a system of this scale.
Choosing a bank voltage
For the same energy, a higher bank voltage needs fewer amp-hours and carries less current, which means thinner cables, smaller fuses and lower losses. As a rough guide:
- 12 volts suits small systems, such as vans, boats and small cabins.
- 24 volts suits medium systems.
- 48 volts is common for homes and larger off-grid systems.
The inverter, charge controller and batteries all need to match the chosen voltage.
Working out daily energy use
Accurate daily energy figures make the biggest difference to the result. List each appliance, its power in watts, and the hours it runs a day. Appliances that cycle on and off, such as fridges, use less than their rated power times 24 hours; the energy label or a plug-in energy meter gives a better figure. Standby loads add up, and the inverter itself uses some power even with nothing switched on. Many designers add a margin, often 10% to 20%, for loads they've forgotten or future additions.
Autonomy and solar charging
Days of autonomy is a trade-off between cost and reliability. More days means a bigger, more expensive bank, but less chance of running out during cloudy weather. Many off-grid systems also use a backup generator for long cloudy spells, which allows fewer days of autonomy. The solar panels must also be large enough to recharge the bank, as well as power daily loads, in the season with the least sun. Our solar panel calculator helps size the panels.
Who uses a solar battery bank calculator
Off-grid homeowners use it to size batteries for cabins and homes. Van and boat owners use it for leisure battery banks. Solar installers use it to design systems and prepare quotes. Preppers and homesteaders use it to plan backup power, and students use it to learn energy storage sizing.
Need more customers from Google?
This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. That is the whole job of DeepRit: a PPC-only agency that sets up and runs Google Ads accounts so every click is accounted for. You keep full ownership of your account, get a written report every week, and can stop at any time. See our pricing or ask for a free audit.
Temperature and ageing
Battery capacity changes with temperature. Cold batteries deliver less capacity, and lithium batteries generally shouldn't be charged below freezing unless they have built-in heating or protection. Hot conditions can shorten battery life. Batteries also lose capacity as they age. Many designers oversize the bank slightly, by perhaps 10% to 25%, to allow for these effects; you can include that margin by lowering the depth of discharge you enter in the solar battery bank calculator.
Safety
Battery banks store a lot of energy and can deliver very high currents. Use correctly sized cables, fuses or breakers on every battery and string, and a battery management system for lithium batteries. Lead-acid batteries can release hydrogen gas while charging, so they need ventilation. Follow the manufacturer's instructions and local electrical regulations, and use a qualified installer for home systems.
Common mistakes
- Underestimating daily energy use, especially standby and fridge loads.
- Using the full rated capacity instead of the usable depth of discharge.
- Forgetting inverter losses for AC loads.
- Choosing too low a bank voltage for a large system.
Wiring batteries in series and parallel
A battery bank is usually built from several smaller batteries. Connecting batteries in series adds their voltages while keeping the same amp-hours: four 12 volt, 100 Ah batteries in series make a 48 volt, 100 Ah bank. Connecting them in parallel adds their amp-hours at the same voltage: four 12 volt, 100 Ah batteries in parallel make a 12 volt, 400 Ah bank. Combining both, called series-parallel, reaches the voltage and capacity you need. Use the solar battery bank calculator's amp-hours at your chosen voltage to work out how many batteries of a given size to buy, and use identical batteries of the same age in a bank, because mismatched batteries can charge and discharge unevenly. For lithium batteries, check the manufacturer's limits on how many can be connected in series or parallel.
DC loads and inverter efficiency
The inverter efficiency figure applies to AC loads, which run through the inverter. If some of your loads run directly from the battery on DC, such as 12 volt lights, pumps or a DC fridge, they don't suffer inverter losses. For a mixed system, you can enter the AC loads with your inverter's efficiency and the DC loads with 100%, then add the two results together. This gives a more accurate size, especially in vans and boats where many loads are DC.
Kilowatt-hours versus amp-hours
Battery capacity is sometimes given in amp-hours and sometimes in kilowatt-hours. Amp-hours only make sense alongside a voltage: 100 Ah at 12 volts is 1.2 kWh, while 100 Ah at 48 volts is 4.8 kWh. When comparing batteries of different voltages, convert both to kilowatt-hours by multiplying amp-hours by voltage and dividing by 1,000. The solar battery bank calculator shows both, so you can compare products on an equal footing.
Charging the bank
The battery bank also has to be charged at a suitable rate. The charge controller, solar array and any backup charger must be able to deliver enough current to refill the bank within the time available, and within the battery's maximum charge rate from its datasheet. Undercharging lead-acid batteries repeatedly can lead to sulphation and lost capacity, while lithium batteries need a charger set to the correct voltages for their chemistry.
Sources and further reading
- Off-the-grid on Wikipedia: living and powering homes without a grid connection.
- Depth of discharge on Wikipedia: how deeply batteries are discharged and its effect on life.
- Lithium iron phosphate battery on Wikipedia: the battery chemistry widely used in solar storage.
Frequently asked questions
How do I size a solar battery bank?
Multiply daily watt-hours by days of autonomy, divide by depth of discharge and inverter efficiency, then divide by the bank voltage for amp-hours.
How many amp-hours do I need for 2 kWh a day?
For 2 days at 24 volts, 80% DoD and 90% efficiency, about 231 Ah.
What depth of discharge should I use?
About 50% for lead-acid and often 80% or more for lithium iron phosphate, following the manufacturer's guidance.
Should I use 12, 24 or 48 volts?
Higher voltages suit larger systems, because they carry less current.
How many days of autonomy do I need?
It depends on your climate and backup options; 1 to 3 days is common.
Is the solar battery bank calculator free?
Yes. It's free, needs no sign-up, and works in your browser.
Free PPC audit
See where your ad budget leaks.
We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.