Inverter Size Calculator
A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call
Free inverter size calculator. Find the continuous rating your power inverter needs, with headroom, and the surge rating for motors and compressors.
- Surge rating needed (W)
- 0
Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.
How to use the inverter size calculator
- Enter the running watts of everything you'll use at the same time. Add the power ratings of all the devices that might be on together, such as a fridge, lights, a laptop and a TV. This is the continuous load.
- Enter the highest surge, if you know it: the brief peak power drawn by the device with the biggest start-up demand, such as a fridge compressor, pump or power tool. Motors often draw several times their running power for a moment when they start.
- Enter the headroom you want above the continuous load, often 25%.
The inverter size calculator shows the continuous rating your inverter should have and the surge rating it must be able to handle.
Continuous and surge ratings
Inverters, which convert DC power from batteries to AC power for household devices, have two key ratings:
- Continuous rating: the power the inverter can supply indefinitely without overheating. Your total running load, with headroom, should stay within it.
- Surge (peak) rating: the higher power it can supply for a short time, often a few seconds or less, to start motors and compressors. Manufacturers state how long the surge can be held.
An inverter that's big enough for the running load can still trip or fail to start a fridge if its surge rating is too low, so both figures matter.
How the inverter size calculator works
Continuous rating = running watts × (1 + headroom ÷ 100)
Surge rating needed = the highest surge you enter
With the default figures, 1,500 running watts with 25% headroom need an inverter with a continuous rating of at least 1,500 × 1.25 = 1,875 watts. If the biggest start-up surge is 3,000 watts, the inverter's surge rating must be at least 3,000 watts. In practice, you'd choose a 2,000 watt inverter with a surge rating of 3,000 watts or more.
A worked example: a camper van
You want to run a 700 watt microwave, about 100 watts of lights and chargers at the same time, so the running load is about 800 watts. A small fridge in the van has a compressor that draws a starting surge you estimate at about 1,800 watts.
- Continuous: 800 × 1.25 = 1,000 watts.
- Surge: at least 1,800 watts.
Enter 800, 1,800 and 25 in the inverter size calculator. A 1,000 watt inverter with a surge rating of 2,000 watts would cover it, though many van owners choose a little larger to allow for future devices.
Pure sine wave or modified sine wave?
- Pure sine wave inverters produce smooth AC power similar to the grid. They suit almost all devices, including motors, compressors, medical equipment, audio equipment and many chargers.
- Modified sine wave inverters are cheaper but produce a stepped waveform. Some devices, especially motors, some chargers and sensitive electronics, may run hotter, noisier or not at all.
For most homes, vans and boats, a pure sine wave inverter is the safer choice.
Finding running and starting watts
Running watts are usually on the device's rating plate or in its manual. If only amps are given, multiply by the voltage: a device rated at 5 amps at 230 volts uses about 1,150 watts. Starting watts are harder to find; motors and compressors commonly draw several times their running power for a short moment, and manufacturers sometimes list a figure. A clamp meter with an inrush function can measure the surge directly. If you can't find a starting figure, many installers allow for a surge of around three times the running watts for motor loads, but check with the manufacturer where possible.
Battery current
The inverter draws a large current from the battery. Divide the inverter's output power by the battery voltage and its efficiency to estimate it:
Battery current ≈ output watts ÷ (battery voltage × efficiency)
A 2,000 watt load on a 12 volt battery at 90% efficiency draws about 2,000 ÷ (12 × 0.9) ≈ 185 amps. That's why large inverters often run from 24 or 48 volt batteries, which need much less current and thinner cables. Use the inverter manufacturer's recommended cable size and fuse, and keep cables between the battery and inverter short.
Who uses an inverter size calculator
Van and RV owners use it to choose an inverter for living off batteries. Boat owners use it for onboard power. Off-grid homeowners and solar installers use it to size the inverter in a solar system. Homeowners use it for backup power during outages, and tradespeople use it for vehicle-mounted inverters for tools.
Need more customers from Google?
This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. That is the whole job of DeepRit: a PPC-only agency that sets up and runs Google Ads accounts so every click is accounted for. You keep full ownership of your account, get a written report every week, and can stop at any time. See our pricing or ask for a free audit.
Efficiency and idle power
Inverters lose some energy as heat, and their efficiency varies with load: many are most efficient in the middle of their range and less efficient at very light loads. An inverter also draws some power with nothing switched on, its idle or no-load consumption. A much larger inverter than you need can waste energy through higher idle power. That's one reason not to oversize too far beyond the inverter size calculator's result. Some inverters have a power-saving mode that reduces idle draw.
Heat and installation
Inverters produce heat, especially near full load, and many reduce their output in high temperatures. Mount them in a dry, ventilated place, away from batteries that can give off gas, with clearance for air flow. Connecting an inverter to a building's wiring normally requires a transfer switch or a suitable installation by a qualified electrician, so it can't feed power back into the grid. Follow the manufacturer's instructions and local electrical rules.
Common mistakes
- Ignoring surge power, so motors and compressors fail to start.
- Adding up every device's watts instead of only those used at the same time, or the reverse, missing devices that run together.
- Choosing a modified sine wave inverter for sensitive devices.
- Using thin cables between the battery and inverter.
Listing your loads
A simple table makes the running load easy to work out. List every device, its running watts, and whether it's likely to be on at the same time as the others. For example, a kettle and a microwave are rarely used at the same moment in a van, but a fridge, lights and phone chargers often are. Add up the group that runs together, and enter that total in the inverter size calculator. Then find the single device with the biggest starting surge. If two motor loads could start at the same moment, such as a pump and a fridge, add their surges together to be safe.
High-power appliances
Devices that heat things, such as kettles, hair dryers, toasters, electric heaters and induction hobs, draw a lot of power, often between 1,000 and 3,000 watts. They don't usually have a large starting surge, but their running power alone can call for a big inverter and a large battery current. Running them from batteries for long periods drains the bank quickly. Many off-grid and van users avoid heavy heating loads on the inverter, or run them only when the sun is strong or a generator is on.
Inverter-chargers and hybrid inverters
Some inverters combine several functions. An inverter-charger can also charge the batteries from shore power or a generator and switch loads over automatically. A hybrid solar inverter can include a solar charge controller and manage the grid, batteries and panels together. These units have the same continuous and surge ratings, so the inverter size calculator applies to them too, but check their charging current and solar input limits as well.
Matching the battery bank
The battery bank must be able to supply the current the inverter draws, including its surge, without the voltage dropping so low that the inverter shuts down. Lithium batteries have a maximum continuous and peak discharge current, set by their battery management system; make sure it exceeds the inverter's demand. Our solar battery bank calculator helps size the bank's capacity for the energy you'll use each day.
Fuses and protection
Fit a suitably rated fuse or circuit breaker in the positive cable close to the battery, sized for the cable and the inverter's maximum current, to protect against short circuits.
Sources and further reading
- Power inverter on Wikipedia: how inverters convert DC to AC and their waveforms.
- Inrush current on Wikipedia: why motors draw a surge when they start.
- Solar inverter on Wikipedia: inverters used in solar power systems.
Frequently asked questions
What size inverter do I need?
Add the running watts of everything used at once, add about 25% headroom, and check that the surge rating covers the largest start-up surge.
What size inverter for 1,500 watts?
At least about 1,875 watts continuous with 25% headroom, so a 2,000 watt inverter.
What is surge power?
The short burst of extra power motors and compressors draw when they start.
Do I need a pure sine wave inverter?
It's recommended for most devices, especially motors and sensitive electronics.
How much current does an inverter draw from a battery?
Roughly the output watts ÷ (battery voltage × efficiency).
Is the inverter size calculator free?
Yes. It's free, needs no sign-up, and works in your browser.
Free PPC audit
See where your ad budget leaks.
We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.