Reactance Calculator
A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call
Free reactance calculator. Find capacitive reactance Xc and inductive reactance XL at any frequency, and the resonant frequency of an LC circuit.
- Inductive reactance XL
- 0
- LC resonant frequency
- 0
Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.
How to use the reactance calculator
- Enter the frequency. You can use SI prefixes: "50" for 50 hertz, "1k" for 1 kilohertz, "2.4G" for 2.4 gigahertz.
- Enter a capacitance, such as "100n" for 100 nanofarads, to find capacitive reactance.
- Enter an inductance, such as "10m" for 10 millihenries or "4.7u" for 4.7 microhenries, to find inductive reactance.
You can fill in any combination. The reactance calculator shows the capacitive reactance (Xc) and inductive reactance (XL) in ohms at that frequency, and, if you enter both a capacitance and an inductance, the LC resonant frequency.
What is reactance?
Reactance is the opposition a capacitor or inductor offers to alternating current. Like resistance, it's measured in ohms, but unlike resistance, it depends on frequency, and it doesn't turn energy into heat: capacitors and inductors store energy and release it again each cycle.
- Capacitors block steady DC but pass high frequencies easily. Their reactance falls as frequency rises.
- Inductors pass DC easily but oppose high frequencies. Their reactance rises with frequency.
This frequency dependence is the basis of filters, tuned circuits, crossovers, oscillators and impedance matching.
How the reactance calculator works
Capacitive reactance: Xc = 1 ÷ (2π × f × C)
Inductive reactance: XL = 2π × f × L
Resonant frequency: f₀ = 1 ÷ (2π × √(L × C))
Here f is the frequency in hertz, C the capacitance in farads, and L the inductance in henries.
With the default figures, at 1 kHz:
- A 100 nF capacitor has a reactance of 1 ÷ (2π × 1,000 × 0.0000001) ≈ 1,591.5 ohms.
- A 10 mH inductor has a reactance of 2π × 1,000 × 0.01 ≈ 62.83 ohms.
- Together, they resonate at 1 ÷ (2π × √(0.01 × 0.0000001)) ≈ 5,033 hertz.
Resonance
At the resonant frequency, the capacitive and inductive reactances are equal, and they cancel each other out. In a series LC circuit, the impedance falls to a minimum, limited only by resistance; in a parallel LC circuit, it rises to a maximum. That's how radio receivers select a station: a tuned circuit resonates at the wanted frequency and rejects others. Resonance is also used in oscillators, filters, wireless charging and induction heating.
You can check resonance with the reactance calculator: enter the resonant frequency it gives, and Xc and XL will be equal.
A worked example: a mains-frequency capacitor
What is the reactance of a 10 µF capacitor at 50 hertz?
- Xc: 1 ÷ (2π × 50 × 0.00001) ≈ 318.3 ohms.
Enter "50" and "10u" in the reactance calculator to check. At 60 hertz, the reactance would be a little lower, about 265 ohms, because reactance falls as frequency rises.
A radio-frequency example
At 100 kHz, a 100 nF capacitor has a reactance of about 15.9 ohms, and a 10 µH inductor about 6.28 ohms. Together, they resonate at about 159 kHz. The same components behave very differently at different frequencies, which is why the reactance calculator asks for the frequency first.
Reactance and impedance
In real circuits, reactance combines with resistance to form impedance, written as Z. Because the current through a reactance is 90 degrees out of step with the voltage, resistance and reactance don't simply add. For a resistor and a capacitor or inductor in series:
|Z| = √(R² + X²)
For example, a 1,000 ohm resistor in series with a capacitor of 1,000 ohms reactance has an impedance of about 1,414 ohms, not 2,000. When a capacitor and an inductor are in series, their reactances subtract, since they act in opposite directions, which is why they cancel at resonance.
Filters and cut-off frequency
A simple RC filter, made from a resistor and a capacitor, has a cut-off frequency where the capacitor's reactance equals the resistance:
f = 1 ÷ (2π × R × C)
Below that frequency, a low-pass RC filter passes signals; above it, it increasingly attenuates them. You can find the cut-off frequency by trying frequencies in the reactance calculator until Xc equals your resistance, or by using the formula directly. Audio crossovers use the same principle with inductors and capacitors to send low frequencies to a woofer and high frequencies to a tweeter.
Who uses a reactance calculator
Electronics engineers use it to design filters, oscillators and matching networks. Radio amateurs use it to build antenna tuners and tuned circuits. Audio designers use it for crossovers and tone controls. Students use it in electronics and physics courses, and technicians use it to understand how components behave at different frequencies.
Need more customers from Google?
This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit manages Google Ads for small and mid-size businesses, and only Google Ads. We check your account before we ever get on a call, then fix the structure, the keywords, the tracking and the ads, with month-to-month terms and no long contract. Book a free audit call.
Real components aren't ideal
The formulas assume ideal components. Real capacitors have some series resistance and inductance from their leads and construction, and above a certain frequency, their self-resonant frequency, they start behaving like inductors. Real inductors have winding resistance and capacitance between turns, so they too have a self-resonant frequency. At high frequencies, the layout of a circuit board, including track lengths, adds stray capacitance and inductance. Component datasheets often list these effects, and they matter more as frequency rises.
Common mistakes
- Forgetting to convert prefixes, such as entering 100 for 100 nF.
- Adding resistance and reactance directly instead of using √(R² + X²).
- Using the wrong frequency unit, such as kilohertz instead of hertz.
- Ignoring component limits at high frequencies.
Choosing a coupling capacitor
Capacitors are often used to pass an AC signal from one stage to another while blocking DC, a job called coupling. A common rule is to choose a capacitor whose reactance at the lowest frequency of interest is small compared with the input resistance of the next stage, often a tenth or less. For example, if an audio input has 10 kΩ resistance and you want to pass signals down to 20 Hz, the capacitor's reactance at 20 Hz should be no more than about 1 kΩ. That needs C = 1 ÷ (2π × 20 × 1,000) ≈ 8 µF, so a 10 µF capacitor would be a sensible choice. Enter "20" and "10u" in the reactance calculator to see that its reactance is about 796 ohms.
Decoupling capacitors
Digital chips and amplifiers draw sudden bursts of current, which can cause noise on the power supply. Small capacitors placed close to each chip's power pins, called decoupling or bypass capacitors, supply those bursts locally. Their low reactance at high frequencies shorts noise to ground. A 100 nF capacitor has a reactance of about 1.6 ohms at 1 MHz and about 0.16 ohms at 10 MHz, which you can check with the reactance calculator. Designers often combine several values, because each capacitor is effective over a different range of frequencies, limited by its self-resonance.
Inductors in power supplies
In switch-mode power supplies, inductors store energy and smooth current at the switching frequency, often tens of kilohertz to several megahertz. Their reactance at the switching frequency is high, so they resist rapid changes in current while passing the DC output. Chokes on mains and signal lines use the same principle to block high-frequency interference while letting low-frequency power or signals through.
Power factor
In AC power systems, motors and transformers are inductive, so their current lags behind the voltage. This lowers the power factor, which means more current flows for the same useful power. Utilities and large users often add capacitors to cancel part of the inductive reactance, a process called power factor correction. The reactance calculator gives the reactance of a capacitor at 50 or 60 hertz, the starting point for sizing such capacitors, though power factor correction is normally designed from the load's reactive power in volt-amperes reactive.
Measuring reactance
An LCR meter measures capacitance, inductance and resistance at a chosen test frequency. Comparing its readings with the reactance calculator's results helps check components and spot ones that have drifted or failed.
Sources and further reading
- Electrical reactance on Wikipedia: capacitive and inductive reactance explained.
- LC circuit on Wikipedia: resonance in inductor-capacitor circuits.
- Electrical impedance on Wikipedia: how resistance and reactance combine.
Frequently asked questions
How do I calculate capacitive reactance?
Xc = 1 ÷ (2π × f × C). A 100 nF capacitor at 1 kHz has about 1,591.5 ohms.
How do I calculate inductive reactance?
XL = 2π × f × L. A 10 mH inductor at 1 kHz has about 62.8 ohms.
What is the resonant frequency of an LC circuit?
f = 1 ÷ (2π × √(L × C)). 10 mH and 100 nF resonate at about 5 kHz.
Why does capacitive reactance fall with frequency?
A capacitor charges and discharges faster at higher frequencies, so it passes more current.
Is reactance the same as resistance?
Both are in ohms, but reactance depends on frequency and stores energy rather than dissipating it.
Is the reactance calculator free?
Yes. It's free, needs no sign-up, and works in your browser.
Free PPC audit
See where your ad budget leaks.
We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.