RC Time Constant Calculator
A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call
Free RC time constant calculator. Enter resistance and capacitance to get τ = RC, the charge level at each time constant and the filter cut-off.
- 5τ (about 99.3% charged)
- 0
- Cut-off frequency
- 0
Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.
How to use the RC time constant calculator
- Enter the resistance, with a prefix if you like: 470, 10k, 4k7 or 1M.
- Enter the capacitance, for example 100u for 100 µF, 47n for 47 nF or 220p for 220 pF.
- Optionally enter the supply voltage to see the capacitor's voltage at each time constant.
The RC time constant calculator shows the time constant τ, the time to charge to about 99.3% (five time constants), the filter cut-off frequency, and a table of how far the capacitor has charged and discharged after one to five time constants.
What is the RC time constant?
When a capacitor charges or discharges through a resistor, its voltage doesn't change instantly. It follows an exponential curve: fast at first, then slower and slower as it approaches the final value. The time constant, written τ (the Greek letter tau), sets the pace:
τ = R × C
With R in ohms and C in farads, τ is in seconds. With the default values, a 10 kΩ resistor and a 100 µF capacitor give τ = 10,000 × 0.0001 = 1 second.
The charging and discharging curves
When charging from zero towards a supply voltage V, the capacitor voltage is:
V_C = V × (1 − e^(−t ÷ τ))
When discharging from V towards zero:
V_C = V × e^(−t ÷ τ)
| Time | Charged | Remaining when discharging |
|---|---|---|
| 1τ | 63.2% | 36.8% |
| 2τ | 86.5% | 13.5% |
| 3τ | 95.0% | 5.0% |
| 4τ | 98.2% | 1.8% |
| 5τ | 99.3% | 0.7% |
After five time constants, the capacitor is considered fully charged or discharged for most practical purposes. The RC time constant calculator shows the same table for your values, with actual voltages if you enter a supply voltage.
A worked example: a 5 V supply
A 10 kΩ resistor charges a 100 µF capacitor from a 5 V supply.
- Time constant: 10,000 × 0.0001 = 1 second.
- After 1 second: 5 × 0.632 ≈ 3.16 V.
- After 3 seconds: 5 × 0.950 ≈ 4.75 V.
- Effectively full: after 5 seconds, at about 4.97 V.
Enter 10k, 100u and 5 in the RC time constant calculator to see this table.
RC filters and the cut-off frequency
A resistor and capacitor together make a simple filter. In a low-pass filter, the signal passes through the resistor and the capacitor connects the output to ground: low frequencies pass, high frequencies are reduced. Swap the positions and you get a high-pass filter. The frequency where the output has fallen to about 70.7% of the input (−3 dB) is the cut-off frequency:
f_c = 1 ÷ (2π × R × C)
For the default 1-second time constant, the cut-off is about 0.159 Hz, very low. A more typical audio filter, with 1 kΩ and 100 nF, has τ = 0.1 ms and a cut-off of about 1.59 kHz. Above the cut-off, a simple first-order RC filter reduces the signal by about 20 dB for every tenfold increase in frequency.
Uses of RC circuits
- Timing and delays: a capacitor charging through a resistor can delay a signal, debounce a switch or hold a reset line low while power stabilises.
- Smoothing: in power supplies, capacitors smooth out ripple from rectified AC.
- Filtering: RC filters remove noise, separate bass from treble, and condition sensor signals.
- Oscillators: RC networks set the frequency of oscillators, including the popular 555 timer.
- Coupling: a capacitor in series passes AC signals between circuit stages while blocking DC.
Who uses an RC time constant calculator
Electronics hobbyists use it for delays, debouncing and simple filters. Students use it to understand exponential charging in physics and electronics courses. Audio enthusiasts use it to design tone controls and crossovers. Engineers use it for quick checks of timing, filtering and power-supply smoothing.
Need more customers from Google?
This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. That is the whole job of DeepRit: a PPC-only agency that sets up and runs Google Ads accounts so every click is accounted for. You keep full ownership of your account, get a written report every week, and can stop at any time. See our pricing or ask for a free audit.
Capacitor values and codes
Small capacitors are often marked with a three-digit code, similar to resistors: two significant figures and a multiplier, giving the value in picofarads. 104 means 10 × 10⁴ pF = 100,000 pF = 100 nF. 473 is 47 nF, and 222 is 2.2 nF. Electrolytic capacitors usually have their value printed directly, such as 100 µF 25 V. Enter the value in the RC time constant calculator using the matching prefix: p for picofarads, n for nanofarads and u for microfarads.
Tolerances and real-world timing
Capacitors often have wide tolerances. Electrolytic capacitors can be ±20% or more, and their value can drift with temperature and age. That means an RC time constant can easily be 20% away from the calculated value. For precise timing, use film or C0G ceramic capacitors with tighter tolerances, or use a crystal or microcontroller timer instead. Leakage in electrolytic capacitors also matters with very large resistors, because the leakage current can stop the capacitor from ever reaching full charge.
Inductors and RL circuits
Inductors combined with resistors have their own time constant, τ = L ÷ R, where L is the inductance in henries. The current in an RL circuit rises and falls along the same exponential curves as the voltage in an RC circuit, reaching about 63.2% after one time constant. The same table of percentages applies.
Common mistakes
- Forgetting unit prefixes: 100 µF is 0.0001 F, not 100 F.
- Expecting full charge after one time constant. It's only 63.2%.
- Confusing τ with the cut-off frequency. They're related by f_c = 1 ÷ (2πτ).
- Ignoring capacitor tolerance when timing matters.
Debouncing a switch
Mechanical switches and buttons don't close cleanly: their contacts bounce for a few milliseconds, producing a burst of on-off pulses that a fast circuit or microcontroller can count as several presses. An RC network smooths those bounces out. A common choice is a 10 kΩ resistor with a 100 nF capacitor, which gives a time constant of 1 millisecond; the capacitor voltage changes too slowly to follow the brief bounces. Bounce times vary widely between switches, from well under a millisecond to several milliseconds, so some designs use a larger capacitor, or combine the RC network with a Schmitt-trigger input that switches cleanly at set thresholds. Enter 10k and 100n in the RC time constant calculator to see that the capacitor reaches about 95% of its final value in 3 milliseconds.
Power-on reset delays
Many circuits need to hold a reset line for a short time after power is applied, so the supply voltage and clock can settle before the circuit starts. A resistor charging a capacitor provides a simple delay: the reset input sees a low voltage at first, which rises as the capacitor charges. The time it takes to cross the chip's threshold depends on the time constant and the threshold as a fraction of the supply. For a threshold at about 63% of the supply, the delay is about one time constant; for 50%, it's about 0.69 time constants, because e^(−0.693) = 0.5.
Finding the time to reach any voltage
To find the time to charge to a particular fraction of the supply, rearrange the charging equation: t = −τ × ln(1 − V_C ÷ V). Charging to 50% takes about 0.693τ, to 90% about 2.303τ, and to 99% about 4.605τ. For discharging to a fraction, t = −τ × ln(V_C ÷ V). These are useful for working out exactly when a timing circuit will switch.
Smoothing capacitors in power supplies
In a power supply, a large capacitor after the rectifier stores charge between the peaks of the AC waveform. The ripple voltage left over depends on the load current, the capacitance and the ripple frequency. A rough estimate for a full-wave rectifier is ripple ≈ load current ÷ (2 × mains frequency × capacitance). For a 1 A load on a 50 Hz supply with a 4,700 µF capacitor, that's about 1 ÷ (100 × 0.0047) ≈ 2.1 V of ripple, which a regulator then removes.
Measuring a time constant
You can measure τ with an oscilloscope: apply a square wave to the RC circuit and watch the capacitor voltage. The time it takes to rise from zero to 63.2% of the step is one time constant. Comparing the measured value with the RC time constant calculator's prediction is a good way to check a capacitor's real value.
Sources and further reading
- RC time constant on Wikipedia: definition and charging curves.
- RC circuit on Wikipedia: filters, cut-off frequency and transient response.
- Capacitor on Wikipedia: types, markings and tolerances.
Frequently asked questions
How do I calculate the RC time constant?
Multiply the resistance in ohms by the capacitance in farads: τ = R × C, in seconds.
How long does a capacitor take to charge fully?
About five time constants, when it reaches about 99.3%.
What percentage is reached after one time constant?
About 63.2% when charging, or 36.8% remaining when discharging.
What is the cut-off frequency of an RC filter?
f_c = 1 ÷ (2πRC).
How do I enter microfarads?
Use u, for example 100u for 100 µF. Use n for nanofarads and p for picofarads.
Is the RC time constant calculator free?
Yes. It's free, needs no sign-up, and works in your browser.
Free PPC audit
See where your ad budget leaks.
We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.