Capacitor Energy Calculator

A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call

Free capacitor energy calculator. Find the energy in joules and the charge in coulombs stored in a capacitor from its capacitance and voltage.

Charge (C)
0
Energy (Wh)
0
Charge (mAh)
0

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the capacitor energy calculator

  1. Enter the capacitance. You can use SI prefixes: "1000u" for 1,000 microfarads, "100n" for 100 nanofarads, "47p" for 47 picofarads, or a plain number in farads, such as "2.5" for a 2.5 farad supercapacitor.
  2. Enter the voltage across the capacitor, in volts.

The capacitor energy calculator shows the energy stored in joules and watt-hours, and the charge stored in coulombs and milliamp-hours.

How the capacitor energy calculator works

The energy stored in a capacitor is:

E = ½ × C × V²

where E is the energy in joules, C is the capacitance in farads, and V is the voltage in volts. The charge stored is:

Q = C × V

where Q is the charge in coulombs.

With the default figures, a 1,000 microfarad capacitor (0.001 farads) charged to 50 volts stores ½ × 0.001 × 50² = 1.25 joules of energy, and 0.001 × 50 = 0.05 coulombs of charge.

The conversions are:

  • Watt-hours = joules ÷ 3,600
  • Milliamp-hours = coulombs ÷ 3.6

Energy grows with the square of voltage

Because voltage is squared, doubling the voltage quadruples the stored energy. A capacitor charged to 100 volts stores four times as much energy as the same capacitor at 50 volts. That's why high-voltage capacitors can be dangerous even when their capacitance looks small, and why the voltage rating matters so much in design.

A worked example: a power supply capacitor

A 470 microfarad capacitor is charged to 400 volts in the input stage of a mains power supply.

  1. Capacitance: 470 µF = 0.00047 F.
  2. Energy: ½ × 0.00047 × 400² = 37.6 joules.
  3. Charge: 0.00047 × 400 = 0.188 coulombs.

Enter "470u" and 400 in the capacitor energy calculator to check. That's enough energy to cause a serious shock or burn, which is why mains equipment can be dangerous even after it's unplugged, until its capacitors have been safely discharged.

Supercapacitors

Supercapacitors, also called ultracapacitors, have very large capacitances, often several farads to thousands of farads, but low voltage ratings, often around 2.5 to 3 volts per cell. A 2.5 farad supercapacitor at 2.7 volts stores ½ × 2.5 × 2.7² ≈ 9.1 joules, about 0.0025 watt-hours, and 6.75 coulombs, about 1.9 milliamp-hours. That's tiny compared with a battery, but supercapacitors can charge and discharge very quickly and survive many more cycles, which makes them useful for memory backup, energy harvesting, regenerative braking and buffering peak loads.

Usable energy

The capacitor energy calculator gives the total energy stored between the given voltage and zero. In practice, a circuit can often use only part of it, because it stops working once the voltage falls below a minimum. The usable energy between two voltages is:

E usable = ½ × C × (V start² − V end²)

For example, if a circuit runs from 5 volts down to 3 volts on a 1 farad capacitor, the usable energy is ½ × 1 × (25 − 9) = 8 joules, compared with 12.5 joules stored at 5 volts. Run the capacitor energy calculator at both voltages and subtract to find it.

Capacitors in series and parallel

  • In parallel, capacitances add: two 100 µF capacitors in parallel make 200 µF at the same voltage, storing twice the energy.
  • In series, the total capacitance falls: two equal capacitors in series give half the capacitance, but the voltage rating doubles. Supercapacitor banks often use series cells with balancing circuits to share the voltage evenly.

Work out the combined capacitance and voltage first, then enter them in the capacitor energy calculator.

Who uses a capacitor energy calculator

Electronics engineers use it to size hold-up capacitors, snubbers and energy storage. Students use it in physics and electronics courses. Hobbyists use it for projects with supercapacitors, flash circuits and coil guns. Repair technicians use it to understand how much energy a capacitor holds before working on equipment, and product designers use it for backup power in devices.

Need more customers from Google?

This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit is a Google Ads agency that does PPC and nothing else: we build the campaigns, block the searches that waste money, write the ads, set up conversion tracking and send you a short report every week. Request a free PPC audit and we will show you, in dollars, what we would fix first.

Voltage ratings and safety margins

Every capacitor has a maximum rated voltage. Exceeding it can damage the dielectric, causing leakage, overheating or failure, and some types, such as electrolytic capacitors, can vent or burst. Designers usually choose a rating with a comfortable margin above the highest voltage the capacitor will see, including spikes. Electrolytic and tantalum capacitors are polarised and must be connected the right way round. Capacitance also varies with temperature, age and, for some ceramic types, the applied voltage, so the real stored energy can differ from the nominal figure.

Discharging capacitors safely

Large or high-voltage capacitors can hold a charge long after power is removed. Before working on equipment, discharge them safely through a suitable resistor rated for the energy and voltage, never with a screwdriver across the terminals, and confirm with a meter that the voltage has fallen to a safe level. Many power supplies include bleeder resistors to discharge capacitors automatically, but they can fail, so always check.

Capacitors compared with batteries

Capacitors store energy in an electric field, while batteries store it chemically. For the same size, batteries hold far more energy, but capacitors can deliver it far faster and handle many more charge cycles. The voltage of a capacitor falls steadily as it discharges, whereas a battery's voltage stays fairly constant for most of its discharge. That's why capacitors are often paired with batteries: the battery provides the energy, and the capacitor handles brief peaks.

Common mistakes

  • Forgetting to convert microfarads to farads, which makes results a million times too large.
  • Treating energy as proportional to voltage instead of voltage squared.
  • Counting all the stored energy as usable, when the circuit stops at a minimum voltage.
  • Assuming an unplugged device is safe without discharging its capacitors.

Hold-up time

A common design question is how long a capacitor can keep a circuit running after the power fails, long enough to save data or shut down safely. If the circuit draws a roughly constant power P, the hold-up time is the usable energy divided by that power:

Time (seconds) ≈ ½ × C × (V start² − V end²) ÷ P

For example, a 1 farad capacitor discharging from 5 volts to 3 volts provides 8 joules of usable energy. A circuit drawing 0.5 watts would run for about 8 ÷ 0.5 = 16 seconds. Use the capacitor energy calculator at both voltages to find the usable energy, then divide by the load's power. Converter efficiency reduces the time slightly, so many designers add a margin. If the load draws a constant current instead of a constant power, the time is C × (V start − V end) ÷ I, using the charge rather than the energy.

Charging time and current

Charging a capacitor through a resistor follows an exponential curve. After one time constant, equal to R × C, the capacitor reaches about 63% of the supply voltage, and after about five time constants it's considered practically full. Our RC time constant calculator works through this. When charging a large capacitor directly from a power supply or battery, the initial current can be very high, limited only by resistance in the circuit, which is why large capacitor banks often use pre-charge resistors to avoid sparks, blown fuses and damaged contacts.

Energy losses in charging

When a capacitor is charged from a fixed-voltage source through a resistor, the energy lost as heat in the resistor equals the energy stored in the capacitor, no matter how large or small the resistance. So charging a capacitor in this simple way is only 50% efficient. Switch-mode and constant-current chargers can do much better. This doesn't change the energy shown by the capacitor energy calculator, but it's useful when working out how much energy a supply must provide.

Units and prefixes

Capacitance values span a huge range, from picofarads in radio circuits to thousands of farads in large supercapacitors. The capacitor energy calculator accepts the common prefixes: p for pico (10⁻¹²), n for nano (10⁻⁹), u for micro (10⁻⁶) and m for milli (10⁻³). Many capacitors are marked with codes rather than full values, such as "104" for 100 nF, where the first two digits are the value and the third is the number of zeros in picofarads. Converting to a clear value before entering it avoids errors of a thousand times or more.

Pulsed power

Camera flashes, defibrillators, spot welders and pulsed lasers all use capacitors to store energy slowly and release it in a short, powerful burst. The capacitor energy calculator shows how much energy is available for each pulse.

Sources and further reading

  • Capacitor on Wikipedia: how capacitors work and the energy they store.
  • Supercapacitor on Wikipedia: high-capacitance, low-voltage energy storage.
  • Joule on Wikipedia: the SI unit of energy.

Frequently asked questions

How do I calculate the energy stored in a capacitor?

E = ½ × C × V², with C in farads and V in volts, gives the energy in joules.

How much energy does a 1,000 µF capacitor at 50 V store?

1.25 joules.

How do I enter microfarads?

Type "u" after the number, such as "1000u" for 1,000 µF, or "n" for nanofarads.

Why does voltage matter so much?

Energy depends on voltage squared, so doubling the voltage stores four times the energy.

How much charge does a capacitor hold?

Q = C × V. A 1,000 µF capacitor at 50 V holds 0.05 coulombs.

Is the capacitor energy calculator free?

Yes. It's free, needs no sign-up, and works in your browser.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep