Wheelchair Ramp Calculator

A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call

Free wheelchair ramp calculator. Find the ramp length for your rise at a 1:12 slope or another ratio, with the angle, grade and landings for long ramps.

Check the accessibility rules that apply where you build. Ramps also need handrails, edge protection and level landings.

Sloped length
0
Angle
0
Grade
0
Intermediate landings
0

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the wheelchair ramp calculator

  1. Measure the total rise: the vertical height from the ground at the bottom to the surface at the top, such as the threshold of a door or the top of a step. Measure straight up, not along a slope.
  2. Choose inches or centimetres.
  3. Enter the slope ratio. The default is 12, for a slope of 1:12: one unit of rise for every 12 units of horizontal run. Enter a larger number, such as 16 or 20, for a gentler ramp.

The wheelchair ramp calculator shows the horizontal run needed, the sloped length of the ramp surface, the angle and grade, and how many intermediate landings a long ramp needs.

Accessibility rules differ between countries, states and building types, and ramps also need handrails, edge protection, a slip-resistant surface and proper landings. Check the rules that apply where you're building, and consider professional advice for public or commercial buildings.

The 1:12 slope

In the US, the 2010 ADA Standards for Accessible Design set a maximum running slope of 1:12 for ramps in new construction, about 8.33% or 4.76°. For every inch of rise, a ramp needs at least 12 inches of run. Many other countries set similar maximums, sometimes gentler, and some allow steeper slopes only for very short rises. A 1:12 slope is a maximum, not a target: gentler slopes, such as 1:16 or 1:20, are easier for many wheelchair users, especially those who self-propel, and for people using walkers.

How the wheelchair ramp calculator works

Run = rise × slope ratio

Sloped length = √(run² + rise²)

Angle = arctan(1 ÷ ratio)

Grade = 100 ÷ ratio (%)

Runs needed = rise ÷ maximum rise per run, rounded up

Intermediate landings = runs − 1

The calculator limits each run to 30 inches (760 mm) of rise, the maximum per run under the ADA Standards, before a level landing is needed.

With the default figures, a rise of 24 inches at 1:12:

  1. Run: 24 × 12 = 288 inches, or 24 feet.
  2. Sloped length: √(288² + 24²) ≈ 289.0 inches.
  3. Angle: about 4.76°, a grade of 8.33%.
  4. Landings: 24 inches is within one run's 30-inch limit, so no intermediate landing is needed.

A worked example: a longer ramp

A front door is 45 inches above the path.

  1. Run at 1:12: 45 × 12 = 540 inches, or 45 feet.
  2. Runs needed: 45 ÷ 30 = 1.5, rounded up to 2.
  3. Intermediate landings: 1.

Enter 45 in the wheelchair ramp calculator to check. The landing adds to the overall length: under the ADA Standards, landings must be at least 60 inches long, and as wide as the ramp, so the total footprint is at least 540 + 60 = 600 inches, 50 feet, if the ramp runs straight. Ramps often turn at landings, in an L or U shape, to fit the available space.

A metric example

A 60 cm rise at 1:12 needs a run of 720 cm, or 7.2 metres. Choose centimetres and enter 60 to check. Since 60 cm is under 76 cm, a single run is enough under the 760 mm limit.

Landings

Level landings are needed at the top and bottom of every ramp run, and wherever a ramp changes direction. They give wheelchair users somewhere to rest, turn and open doors. Under the ADA Standards, landings are at least as wide as the ramp run leading to them and at least 60 inches (1,525 mm) long, with larger landings where a ramp changes direction. Space for a door to swing, and room to manoeuvre at it, often makes the top landing larger still.

Other key requirements

Ramp rules usually cover much more than slope. Under the ADA Standards, for example:

  • Clear width: at least 36 inches between handrails.
  • Cross slope: no more than 1:48, so the ramp doesn't tilt sideways.
  • Handrails: on both sides when a ramp rises more than 6 inches.
  • Edge protection: to stop wheels and feet slipping off the sides.
  • Surface: firm, stable and slip-resistant, with drainage outdoors.

Residential ramps for private homes may not be covered by the same rules, but they're a sensible guide for safety and usability.

Temporary and portable ramps

For a single step or a small threshold, portable ramps are common. Manufacturers usually recommend a length for each rise and type of user. Wheelchairs pushed by an assistant, and powered wheelchairs and scooters, can often manage steeper slopes than people propelling themselves, which is why some portable ramp guides suggest slopes such as 1:8 or 1:6 for assisted use over short rises. Use the wheelchair ramp calculator with the ratio the manufacturer recommends for your situation.

Who uses a wheelchair ramp calculator

Homeowners and families use it when adapting a home for a wheelchair user. Builders and contractors use it to plan ramps and quote for materials. Occupational therapists use it when recommending home adaptations. Architects and facility managers use it for accessible design, and community groups use it when improving access to their buildings.

Get the next job from Google

Homeowners search Google when something breaks. Search ads put a local trade business at the top of those searches. DeepRit is a Google Ads agency that does PPC and nothing else: we build the campaigns, block the searches that waste money, write the ads, set up conversion tracking and send you a short report every week. Request a free PPC audit and we will show you, in dollars, what we would fix first.

Planning the layout

Before building, mark the ramp's full footprint on the ground, including landings and any turns, and check it fits the available space without blocking paths, driveways or drainage. A long straight ramp is easiest to use but needs a lot of space; switchback designs fit more ramp into a smaller area. Consider where rainwater will drain, whether the surface will be in shade and stay icy in winter, and how the ramp meets the door threshold. If the run would be very long, a platform lift may be a better option.

Materials

Ramps can be built from timber, concrete, aluminium or steel. Modular aluminium systems are quick to install and can be adapted as needs change. Timber is versatile but needs a slip-resistant finish and regular maintenance. Concrete is durable and suits permanent ramps. Whatever the material, the slope, landings, width and handrails matter more than the material itself.

Common mistakes

  • Measuring the rise along a sloping path instead of vertically.
  • Treating 1:12 as a target rather than the steepest allowed slope.
  • Forgetting landings, which add length and are required on long ramps.
  • Leaving out handrails and edge protection.

Comparing slopes

The slope ratio has a big effect on the ramp's length. For a 24-inch rise:

Slope Run Angle
1:12 24 ft about 4.76°
1:16 32 ft about 3.58°
1:20 40 ft about 2.86°

A gentler slope is easier to climb and safer to descend, but needs more space and material. Try different ratios in the wheelchair ramp calculator to find a balance between usability and the space available. Many accessibility guides suggest choosing the gentlest slope the site allows.

Who will use the ramp?

Think about the people who'll use the ramp. Someone propelling a manual wheelchair needs a gentle slope and regular rest landings, especially on long ramps. A person using a powered wheelchair or mobility scooter can usually manage the maximum slope but needs enough width and turning space. Carers pushing a wheelchair need firm footing and handrails. People who walk with sticks or frames also benefit from ramps, but some find shallow steps easier, so many accessible entrances offer both a ramp and steps. An occupational therapist can assess individual needs and recommend a suitable design.

Permits

Permanent ramps, especially larger ones attached to buildings or crossing property boundaries, may need permission from the local planning or building control authority. Rules vary, so check before building. Contractors who regularly build ramps usually know the local requirements and can handle applications.

Measuring the rise accurately

Lay a long, straight board level from the threshold out over the ground, check it with a spirit level, and measure straight down to the ground where the ramp will start. If the ground slopes, the rise at the far end of a long ramp may differ from the rise at the door.

Sources and further reading

Frequently asked questions

How long should a wheelchair ramp be?

At 1:12, the run is 12 times the rise: 24 inches of rise needs 24 feet of run.

What is the maximum slope for a wheelchair ramp?

1:12 under the ADA Standards for new construction; gentler is easier to use.

When does a ramp need a landing?

At the top and bottom, at turns, and at least every 30 inches of rise under the ADA Standards.

What angle is a 1:12 slope?

About 4.76°, a grade of 8.33%.

Do ramps need handrails?

Under the ADA Standards, yes, on both sides when the rise is more than 6 inches.

Is the wheelchair ramp calculator free?

Yes. It's free, needs no sign-up, and works in your browser.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep