Wet Bulb Temperature Calculator From Heat and Humidity

A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call

Free wet bulb temperature calculator. Estimate wet-bulb temperature from air temperature and relative humidity with the Stull formula, in °C or °F.

In the other unit
0
Wet-bulb depression (°C)
0

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the wet bulb temperature calculator

  1. Enter the air temperature, the ordinary temperature shown by a thermometer in the shade, sometimes called the dry-bulb temperature.
  2. Choose °C or °F.
  3. Enter the relative humidity as a percentage, from a weather forecast, a weather station or a hygrometer.

The wet bulb temperature calculator shows the wet-bulb temperature in your chosen unit and the other unit, and the wet-bulb depression: how many degrees the wet-bulb temperature is below the air temperature.

What is wet-bulb temperature?

The wet-bulb temperature is the lowest temperature that air can cool something to by evaporating water. Traditionally, it's measured with a thermometer whose bulb is wrapped in a wet cloth, with air moving over it. Water evaporates from the cloth, taking heat with it, so the thermometer reads lower than the air temperature. In dry air, water evaporates quickly and the wet bulb reads much lower; in humid air, evaporation slows, and the wet bulb reads close to the air temperature. At 100% humidity, no net evaporation happens, and the wet-bulb and air temperatures are the same.

The wet-bulb temperature matters for people because we cool ourselves the same way: by sweating and letting the sweat evaporate. When the wet-bulb temperature is high, sweat can't evaporate quickly enough to remove the body's heat, and the risk of heat illness rises sharply, even in a fit, healthy person resting in the shade.

How the wet bulb temperature calculator works

The calculator uses an empirical formula published by the meteorologist Roland Stull in 2011, which estimates the wet-bulb temperature from air temperature (T, in °C) and relative humidity (RH, in %):

Tw = T × atan(0.151977 × √(RH + 8.313659)) + atan(T + RH) − atan(RH − 1.676331) + 0.00391838 × RH^1.5 × atan(0.023101 × RH) − 4.686035

where atan is the arctangent in radians. Stull's formula is designed for sea-level pressure and for relative humidity from about 5% to 99% and air temperatures from about −20 °C to 50 °C. Within that range, it's usually accurate to within about 1 °C. If you enter °F, the calculator converts to °C first and converts the answer back.

With the default figures, an air temperature of 30 °C at 60% relative humidity gives a wet-bulb temperature of about 24.0 °C (75.2 °F), a depression of about 6 °C.

Examples

Air temperature Relative humidity Wet-bulb temperature
20 °C 50% about 13.7 °C
30 °C 60% about 24.0 °C
35 °C 60% about 28.5 °C
35 °C 75% about 31.1 °C
40 °C 30% about 25.9 °C

Notice that a hot, dry day at 40 °C and 30% humidity has a lower wet-bulb temperature than a slightly cooler, humid day at 35 °C and 60%. That's why humid heat can be more dangerous than dry heat at a higher thermometer reading.

Wet-bulb temperature and human limits

A widely cited 2010 study by Steven Sherwood and Matthew Huber proposed that a sustained wet-bulb temperature of 35 °C is the upper limit of human survival, because above it even a healthy person at rest in the shade can't shed enough heat. More recent laboratory experiments, including a 2022 study from Pennsylvania State University, found that young, healthy people reached their limit at lower wet-bulb temperatures, around 30 to 31 °C in warm, humid conditions, and lower still in hot, dry conditions. Older adults, children, people with health conditions and people doing physical work are at risk at lower values still.

Wet-bulb temperatures above about 31 °C remain rare but are occurring more often in parts of South Asia, the Persian Gulf and other hot, humid regions. The wet bulb temperature calculator shows a warning when the result reaches that level.

A worked example in Fahrenheit

On a summer afternoon, the temperature is 95 °F with 50% relative humidity.

  1. Convert: 95 °F = 35 °C.
  2. Wet-bulb temperature: about 26.6 °C.
  3. In Fahrenheit: about 79.9 °F.

Choose °F in the wet bulb temperature calculator and enter 95 and 50 to check.

Wet-bulb temperature and the heat index

The heat index, often reported in the US, combines temperature and humidity into a "feels like" temperature. The wet-bulb globe temperature (WBGT), used by many sports bodies, militaries and workplaces, goes further, combining the wet-bulb temperature with readings that capture sunshine and wind. The plain wet-bulb temperature from this calculator is one part of WBGT, and a direct measure of how well evaporation can cool. Our heat index calculator shows the "feels like" figure.

Who uses a wet bulb temperature calculator

Athletes, coaches and event organisers use it to judge heat risk for training and competition. Outdoor workers and safety managers use it to plan work and rest. Farmers use it to assess heat stress in livestock. HVAC engineers use wet-bulb temperatures to size cooling towers and evaporative coolers, and students use it to learn atmospheric science.

Need more customers from Google?

This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit manages Google Ads for small and mid-size businesses, and only Google Ads. We check your account before we ever get on a call, then fix the structure, the keywords, the tracking and the ads, with month-to-month terms and no long contract. Book a free audit call.

Evaporative cooling

The wet-bulb temperature also sets the limit for evaporative coolers, sometimes called swamp coolers, which cool air by passing it over wet pads. In dry climates, where the wet-bulb depression is large, they work well and use little energy. In humid climates, where the wet-bulb temperature is close to the air temperature, they can barely cool the air. Cooling towers in power stations and large buildings work on the same principle, and their performance is rated against the local wet-bulb temperature.

Staying safe in humid heat

When wet-bulb temperatures are high, public health advice usually includes drinking water regularly, avoiding strenuous activity in the hottest part of the day, resting in the shade or in air-conditioned spaces, wearing light, loose clothing, and checking on older neighbours and relatives. Fans help in moderate conditions but become less effective, and can even add heat, when the air is very hot. Know the signs of heat exhaustion and heat stroke, such as confusion, a very high body temperature, and hot skin, and seek urgent help if they appear.

Common mistakes

  • Entering °F with °C selected.
  • Using the formula far outside its tested range, such as very low humidity or freezing temperatures.
  • Confusing wet-bulb temperature with the heat index or the "feels like" temperature.
  • Assuming dry heat is always more dangerous than humid heat at a lower temperature.

Measuring wet-bulb temperature yourself

A sling psychrometer measures wet-bulb temperature directly. It has two thermometers side by side: one ordinary, and one with its bulb covered by a wet cotton wick. You whirl it through the air for a minute or two so air flows over the wick, then read both thermometers. The wet one reads lower because of evaporation. The difference, the wet-bulb depression, tells you how dry the air is. Electronic weather stations and many heat-stress meters now estimate the wet-bulb temperature from temperature and humidity sensors, using formulas like the one in the wet bulb temperature calculator.

Wet-bulb temperature at altitude

Stull's formula assumes sea-level air pressure. At higher altitudes, where the air is thinner, water evaporates a little more readily, so the true wet-bulb temperature is slightly lower than the formula suggests. The difference is small at moderate elevations but grows on high mountains. For precise work at altitude, use a psychrometric calculation that includes air pressure.

Wet-bulb temperature and the dew point

The wet-bulb temperature always lies between the dew point and the air temperature. In dry air, it's roughly a third of the way from the dew point to the air temperature; at 100% humidity, all three are the same. If you know the dew point instead of the relative humidity, our relative humidity calculator converts it to relative humidity, which you can then enter here.

Animals and crops

Livestock, especially dairy cows, pigs and poultry, are vulnerable to humid heat because they can't sweat as effectively as people. Farmers use indices that combine temperature and humidity to decide when to add shade, fans or sprinklers. Plants cool themselves by releasing water vapour through their leaves, and humid heat limits that cooling too, which can reduce crop yields during heatwaves.

Planning outdoor events

Sports governing bodies, schools and event organisers increasingly set rules based on heat-stress measures, such as shortening matches, adding cooling breaks or moving events to cooler times when readings pass set thresholds. Checking the forecast temperature and humidity in advance with the wet bulb temperature calculator helps plan safer schedules, adequate shade and water, and trained staff on hand.

Sources and further reading

Frequently asked questions

How do I calculate wet-bulb temperature?

Enter the air temperature and relative humidity; the calculator uses Stull's formula to estimate it.

What is the wet-bulb temperature at 30 °C and 60% humidity?

About 24.0 °C.

What wet-bulb temperature is dangerous?

Risk rises steeply in the high 20s °C; studies suggest healthy young people reach their limit around 30 to 31 °C, and 35 °C is often cited as the theoretical survival limit.

Why is the wet-bulb temperature lower than the air temperature?

Evaporation removes heat; in drier air, more evaporation means a bigger difference.

When are they the same?

At 100% relative humidity.

Is the wet bulb temperature calculator free?

Yes. It's free, needs no sign-up, and works in your browser.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep