Serum Osmolality Calculator With Osmolal Gap (US and SI)
A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call
Free serum osmolality calculator. Estimate plasma osmolality from sodium, glucose and urea, and the osmolal gap from a measured value.
For education only. Interpret results with a clinician.
- Osmolal gap
- 0
Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.
How to use the serum osmolality calculator
- Choose the units: US units, with glucose and blood urea nitrogen (BUN) in mg/dL, or SI units, with glucose and urea in mmol/L.
- Enter the serum sodium in mEq/L (the same as mmol/L).
- Enter the glucose and BUN or urea.
- Optionally enter the measured osmolality from the laboratory, to calculate the osmolal gap.
- Optionally enter the blood ethanol level, in mg/dL for US units or mmol/L for SI units, to include it in the calculated osmolality.
The serum osmolality calculator shows the calculated osmolality in mOsm/kg and, if you entered a measured value, the osmolal gap.
This calculator is for education and to support clinical judgement. Interpreting osmolality and the osmolal gap, especially in suspected poisoning, requires a qualified clinician and laboratory confirmation.
What is serum osmolality?
Osmolality measures the concentration of dissolved particles in the blood, per kilogram of water. It reflects the body's water balance: when there's too little water relative to solutes, osmolality rises; when there's too much, it falls. The body keeps osmolality within a narrow range, often quoted as roughly 275 to 295 mOsm/kg, through thirst and the hormone that controls how much water the kidneys keep.
Sodium and its accompanying anions make up most of the osmolality, with smaller contributions from glucose and urea.
How the serum osmolality calculator works
US units: calculated osmolality = 2 × Na + glucose ÷ 18 + BUN ÷ 2.8
SI units: calculated osmolality = 2 × Na + glucose + urea
Sodium is doubled to account for its accompanying anions, mainly chloride and bicarbonate. Dividing glucose by 18 and BUN by 2.8 converts mg/dL to mmol/L.
With the default figures, a sodium of 140, glucose of 90 mg/dL and BUN of 14 mg/dL give 2 × 140 + 90 ÷ 18 + 14 ÷ 2.8 = 280 + 5 + 5 = 290 mOsm/kg.
If you enter ethanol, it's added as ethanol ÷ 3.7 for mg/dL, or as the value itself for mmol/L. Some references use a factor of 4.6 instead of 3.7; 3.7 is often used because it reflects ethanol's measured contribution to osmolality more closely.
The osmolal gap
Osmolal gap = measured osmolality − calculated osmolality
The measured osmolality from the laboratory includes every dissolved particle, while the calculated value includes only sodium, glucose and urea. A normal gap is small, often quoted as less than about 10 mOsm/kg, though normal ranges vary between laboratories and studies.
With the default figures, a measured osmolality of 300 and a calculated value of 290 give a gap of 10 mOsm/kg.
A raised gap means unmeasured particles are present. Causes include ethanol, toxic alcohols such as methanol and ethylene glycol, mannitol, and some other substances and conditions. Toxic alcohol poisoning is a medical emergency, and a normal gap doesn't rule it out, particularly later after ingestion, when the alcohol has been metabolised. Clinicians interpret the gap alongside the history, acid-base results and specific tests.
A worked example: SI units
A patient has a sodium of 138 mmol/L, glucose of 5 mmol/L and urea of 5 mmol/L, with a measured osmolality of 310 mOsm/kg.
- Calculated osmolality: 2 × 138 + 5 + 5 = 286 mOsm/kg.
- Osmolal gap: 310 − 286 = 24 mOsm/kg.
Choose SI units in the serum osmolality calculator and enter these figures to check. A gap that size would prompt clinicians to look for an unmeasured osmole.
Including ethanol
If the same US-units patient from the default example had a measured osmolality of 330 and a blood ethanol of 100 mg/dL, the calculated osmolality including ethanol would be 290 + 100 ÷ 3.7 ≈ 317, and the gap about 13 mOsm/kg. Without accounting for ethanol, the gap would appear to be 40. Including a known ethanol level helps show whether something else might also be present.
Osmolality and osmolarity
The two terms are often used interchangeably, but they differ slightly. Osmolality is particles per kilogram of water, which is what laboratories measure, usually by freezing point depression. Osmolarity is particles per litre of solution. In blood, the difference is small, and the calculated value is commonly compared directly with the measured osmolality.
Who uses a serum osmolality calculator
Emergency and intensive care doctors use it to assess sodium disorders and suspected poisoning. Toxicologists use the osmolal gap as one clue to toxic alcohols. Nephrologists and endocrinologists use osmolality when investigating water balance. Laboratory scientists use it to check results, and medical and nursing students use it to learn physiology.
Need more customers from Google?
This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit is a Google Ads agency that does PPC and nothing else: we build the campaigns, block the searches that waste money, write the ads, set up conversion tracking and send you a short report every week. Request a free PPC audit and we will show you, in dollars, what we would fix first.
Effective osmolality
Urea crosses cell membranes freely, so it doesn't draw water out of cells. Effective osmolality, also called tonicity, leaves urea out: 2 × Na + glucose ÷ 18 in US units. It's the figure used, for example, when assessing hyperosmolar hyperglycaemic state, where a high effective osmolality is one of the defining features. A patient with kidney failure can have a high total osmolality from urea, but normal tonicity.
Common mistakes
- Mixing US and SI units, such as entering glucose in mmol/L with US units selected.
- Confusing BUN with urea: BUN in mg/dL and urea in mmol/L use different factors.
- Relying on a normal gap to exclude toxic alcohol poisoning.
- Comparing results across laboratories without checking their normal ranges.
Low osmolality
Low serum osmolality, below the normal range, usually means there's too much water relative to solutes, and it's most often seen with low sodium. Causes include drinking very large amounts of water, conditions where the body retains water inappropriately, and some heart, liver and kidney diseases. Checking the measured osmolality helps clinicians tell true hyponatraemia, where osmolality is low, from situations where sodium is low but osmolality is normal or high, such as very high glucose or pseudohyponatraemia. Our corrected sodium calculator adjusts sodium for high glucose.
High osmolality
High osmolality usually means too little water relative to solutes, as in dehydration or hypernatraemia, or the presence of extra solutes such as glucose, urea in kidney failure, or alcohols. The serum osmolality calculator separates the contributions of sodium, glucose and urea, which helps show where a high value comes from. For example, a patient with a sodium of 140 and glucose of 900 mg/dL has a calculated osmolality of about 2 × 140 + 900 ÷ 18 + BUN ÷ 2.8, which is 330 plus the urea contribution, almost entirely due to glucose rather than sodium.
Why the ethanol factor varies
Different studies have measured slightly different contributions of ethanol to osmolality, which is why both 3.7 and 4.6 appear in references. The factor 4.6 comes from ethanol's molecular weight, about 46, converting mg/dL to mmol/L. The factor 3.7 comes from studies comparing measured and calculated values, and suggests ethanol raises measured osmolality a little more than its molecular weight alone predicts. The serum osmolality calculator uses 3.7, which gives a slightly larger ethanol contribution and a smaller remaining gap.
How osmolality is measured
Laboratories usually measure osmolality with an osmometer that detects the freezing point of the sample: the more particles dissolved, the lower the freezing point. Some older osmometers measured vapour pressure instead, which doesn't detect volatile substances such as alcohols, so those methods can't be used to look for an osmolal gap from alcohols. Ask the laboratory which method it uses if the result will be used in suspected poisoning.
Timing of samples
For an osmolal gap to be meaningful, the measured osmolality and the sodium, glucose and urea used in the calculation should come from samples taken at the same time. Values can change quickly in unwell patients, especially during treatment, so results from different times can give a misleading gap.
Urine osmolality
Urine osmolality, measured separately, shows how concentrated the urine is. Comparing it with serum osmolality helps clinicians understand how the kidneys are handling water, for example when investigating low or high sodium. The serum osmolality calculator covers blood only.
Sources and further reading
- Osmol gap on Wikipedia: the calculation and causes of a raised gap.
- Plasma osmolality on Wikipedia: normal ranges and how osmolality is regulated.
- Purssell RA, Pudek M, Brubacher J, Abu-Laban RB. Derivation and validation of a formula to calculate the contribution of ethanol to the osmolal gap. Ann Emerg Med. 2001.
Frequently asked questions
How do I calculate serum osmolality?
2 × Na + glucose ÷ 18 + BUN ÷ 2.8 in US units, or 2 × Na + glucose + urea in SI units.
What is a normal serum osmolality?
Often quoted as roughly 275 to 295 mOsm/kg, though laboratory ranges vary.
What is the osmolal gap?
Measured osmolality minus calculated osmolality.
What causes a high osmolal gap?
Unmeasured particles such as ethanol, methanol, ethylene glycol or mannitol, among others.
Does a normal gap rule out poisoning?
No. Clinicians use other tests and the history too.
Is the serum osmolality calculator free?
Yes. It's free, needs no sign-up, and works in your browser.
Free PPC audit
See where your ad budget leaks.
We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.