RAID Calculator
A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call
Free RAID calculator. Find usable storage, efficiency and how many drive failures an array survives for RAID 0, 1, 5, 6 and 10.
- Raw capacity (TB)
- 0
- Storage efficiency
- 0
- Survives failure of
- 0
Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.
How to use the RAID calculator
- Enter the number of drives in the array.
- Enter the size of each drive in terabytes (TB). If your drives are different sizes, enter the size of the smallest, since most RAID levels treat every drive as that size.
- Choose the RAID level: 0, 1, 5, 6 or 10.
The RAID calculator shows the usable capacity, the raw capacity, the storage efficiency, and how many drives can fail without losing data.
What is RAID?
RAID, short for redundant array of independent (originally inexpensive) disks, combines several drives into one storage unit. Depending on the level, RAID can improve speed, protect against drive failure, or both, at the cost of some capacity. RAID is widely used in servers, network-attached storage (NAS) devices and workstations.
RAID levels and capacity
The RAID calculator uses these formulas for usable capacity, where n is the number of drives and s the size of each drive:
| Level | How it works | Usable capacity | Minimum drives | Drive failures tolerated |
|---|---|---|---|---|
| RAID 0 | Striping, no redundancy | n × s | 2 | 0 |
| RAID 1 | Mirroring | s | 2 | n − 1 |
| RAID 5 | Striping with single parity | (n − 1) × s | 3 | 1 |
| RAID 6 | Striping with double parity | (n − 2) × s | 4 | 2 |
| RAID 10 | Mirrored pairs, striped | n ÷ 2 × s | 4 | 1 per mirrored pair |
With the default figures, four 8 TB drives in RAID 5 give (4 − 1) × 8 = 24 TB of usable space from 32 TB of raw capacity, a storage efficiency of 75%. The array can survive one drive failure.
Comparing levels for four 8 TB drives
- RAID 0: 32 TB usable, 100% efficiency, but no protection: if any drive fails, all data is lost.
- RAID 5: 24 TB usable, 75% efficiency, survives one failure.
- RAID 6: 16 TB usable, 50% efficiency with four drives, survives any two failures.
- RAID 10: 16 TB usable, 50% efficiency, survives one failure in each mirrored pair, and often gives good write performance.
Run each level in the RAID calculator to compare. As you add more drives, RAID 5 and RAID 6 become more efficient, because the parity overhead is spread across more drives: eight 12 TB drives in RAID 6 give 72 TB usable, 75% efficiency.
A worked example: a six-drive NAS
A small office NAS has six 4 TB drives in RAID 6.
- Raw capacity: 6 × 4 = 24 TB.
- Usable: (6 − 2) × 4 = 16 TB.
- Efficiency: 16 ÷ 24 ≈ 66.7%.
- Protection: any two drives can fail without data loss.
Enter 6, 4 and RAID 6 in the RAID calculator to check.
Terabytes and tebibytes
Drive manufacturers measure capacity in decimal units, where 1 TB is 1,000,000,000,000 bytes. Many operating systems report capacity in binary units, where 1 TiB is 1,099,511,627,776 bytes, often still labelled "TB". That's why an 8 TB drive may show as about 7.28 TB in your operating system. The RAID calculator works in whatever unit you enter, so the usable figure will show the same difference. File systems also reserve some space, so the space available for files is a little lower.
Rebuilds and large drives
When a drive fails in a redundant array, the array keeps running in a degraded state until the failed drive is replaced and its data rebuilt from the others. Rebuilding large drives can take many hours or days, during which the array is under extra load and, in RAID 5, has no remaining protection. A second failure, or an unreadable sector on another drive during the rebuild, can cause data loss. For this reason, many administrators prefer RAID 6 or RAID 10 for arrays of large drives, and keep spare drives on hand.
RAID isn't a backup
RAID protects against some drive failures, but it doesn't protect against accidental deletion, file corruption, ransomware, theft, fire, controller failure or multiple drive failures. Changes, including mistakes, are copied across the array instantly. Keep separate backups of important data, ideally following a strategy such as the 3-2-1 rule: three copies of your data, on two different types of media, with one copy off-site.
Mixed drive sizes
In standard RAID levels, each drive is treated as the size of the smallest drive in the array, so larger drives waste their extra space. Some NAS systems offer flexible schemes that make better use of mixed drive sizes; their capacity calculations differ from standard RAID. If you plan to upgrade drives later, check how your system handles mixed sizes.
Performance
RAID levels also differ in speed. RAID 0 stripes data across all drives, giving fast reads and writes. RAID 1 can read quickly from either drive but writes at the speed of one. RAID 5 and RAID 6 read well, but writes are slower because parity has to be calculated and written, especially for small random writes. RAID 10 generally offers good read and write performance, which is why it's popular for databases. Controllers, caching and drive types also affect performance.
Who uses a RAID calculator
System administrators use it to plan server and NAS storage. Home users use it when setting up a NAS for media and backups. Video editors and photographers use it to plan fast, safe working storage. IT consultants use it to quote storage solutions, and students use it to learn storage concepts.
Need more customers from Google?
This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit is a Google Ads agency that does PPC and nothing else: we build the campaigns, block the searches that waste money, write the ads, set up conversion tracking and send you a short report every week. Request a free PPC audit and we will show you, in dollars, what we would fix first.
Common mistakes
- Treating RAID as a backup.
- Choosing RAID 0 for important data, which has no redundancy.
- Using RAID 5 with very large drives without considering rebuild risk.
- Mixing drive sizes and expecting to use the full capacity.
Hot spares
A hot spare is an extra drive installed in the system but not used for data. If a drive in the array fails, the controller or NAS automatically starts rebuilding onto the spare, shortening the time the array is unprotected. A hot spare doesn't add usable capacity, so it isn't included in the RAID calculator's figures; leave it out of the number of drives you enter. For arrays where downtime matters, or where nobody may notice a failure quickly, a hot spare is a common precaution.
Hardware and software RAID
RAID can be managed by a dedicated hardware controller, by the operating system, or by the storage software on a NAS. Hardware RAID controllers often include their own cache and can take load off the computer's processor, but an array may depend on that controller model to be read. Software RAID and NAS systems are flexible and widely used, and many file systems offer RAID-like features of their own, with built-in checks against silent data corruption. The capacity formulas in the RAID calculator apply to the standard levels whichever method you use, though some systems have their own variations.
Planning for growth
Storage needs usually grow. When planning an array, consider how much space you'll need in two to five years, not just today. Some systems let you expand an array by adding drives or replacing drives with larger ones one at a time, while others require you to build a new array. Leaving free drive bays, or choosing larger drives from the start, can save a difficult migration later. Use the RAID calculator to compare options, such as four large drives now versus six smaller ones.
Drive choice
Drives designed for NAS and server use are built for continuous operation and for working in arrays, and they handle errors in a way that suits RAID controllers. Desktop drives may cause problems in some arrays. Many administrators also avoid buying all the drives for an array from the same batch, to reduce the chance of several failing at around the same time.
Monitoring
Most RAID controllers and NAS systems can send an email or notification when a drive reports errors or fails. Enable these alerts and check the array's health regularly, so a failed drive is replaced promptly.
Solid-state drives
Solid-state drives can also be used in RAID. They're much faster than hard drives and rebuild faster, but they have their own wear characteristics, so check the manufacturer's guidance on their use in arrays.
Sources and further reading
- RAID on Wikipedia: the history and concepts of RAID.
- Standard RAID levels on Wikipedia: RAID 0, 1, 5 and 6 in detail.
- Nested RAID levels on Wikipedia: RAID 10 and other combinations.
Frequently asked questions
How much usable space does RAID 5 give?
The total of all drives minus one drive: four 8 TB drives give 24 TB.
How much does RAID 6 give?
The total minus two drives: six 4 TB drives give 16 TB.
What is RAID 10's capacity?
Half the total: four 8 TB drives give 16 TB.
Which RAID level is safest?
RAID 6 and RAID 10 tolerate more failures than RAID 5; RAID 1 mirrors everything. None replace backups.
Why does my drive show less than its rated size?
Manufacturers use decimal terabytes, while many systems report binary units.
Is the RAID calculator free?
Yes. It's free, needs no sign-up, and works in your browser.
Free PPC audit
See where your ad budget leaks.
We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.