Percent Error Calculator

A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call

Free percent error calculator. Compare a measured value with the true value to get the percent error, signed error, absolute error and relative error.

Absolute error
0
Signed percent error
0
Relative error
0

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the percent error calculator

  1. Enter the measured value: the result you got from your experiment, test or estimate.
  2. Enter the true value: the accepted, theoretical or known correct value.
  3. Read the results. The percent error calculator shows the percent error, the signed percent error (which tells you whether you were high or low), the absolute error and the relative error.

Negative numbers and decimals are fine. The only value that can't be used as the true value is zero, because percent error divides by it.

The percent error formula

Percent error = |measured − true| ÷ |true| × 100

The vertical bars mean "absolute value": ignore any minus sign. So percent error is always positive, and tells you how far off you were as a share of the true value.

For a pendulum experiment that measured gravity as 9.6 m/s² when the accepted value is 9.81 m/s²:

  • Difference: 9.6 − 9.81 = −0.21
  • Absolute error: 0.21
  • Divided by the true value: 0.21 ÷ 9.81 = 0.0214
  • Percent error: 2.14%

Signed percent error

Sometimes it matters which way you were wrong. The signed version keeps the sign:

Signed percent error = (measured − true) ÷ |true| × 100

In the gravity example it's −2.14%: the measurement came out low. A positive result means the measurement was too high.

The direction often hints at the cause. A pendulum result that's consistently low might mean the string stretched or the timing started late. A scale that always reads high needs recalibrating. Random errors scatter both ways; systematic errors push one way every time.

Absolute and relative error

  • Absolute error is the plain difference, |measured − true|, in the original units: 0.21 m/s².
  • Relative error is the absolute error divided by the true value, as a decimal: 0.0214.
  • Percent error is the relative error × 100: 2.14%.

Absolute error alone can be misleading. Being 2 cm off when measuring a 10-metre room is excellent (0.2%), but being 2 cm off when measuring a 5 cm screw is terrible (40%). Percent error puts errors on the same scale.

What counts as a good percent error?

It depends entirely on the field and the equipment:

  • School science labs: under 5% is usually considered good, and under 10% acceptable. Simple equipment and human timing limit precision.
  • University and research labs: often under 1%, sometimes far smaller.
  • Manufacturing: tolerances are set per part; precision engineering may need errors below 0.01%.
  • Estimates and forecasts: a sales forecast within 10% might be very good.

Always say how you measured and what limited your accuracy. A 3% error with a stopwatch is reasonable; a 3% error with a precision balance suggests a mistake.

Percent error vs percent difference vs percent change

These three are easy to mix up:

  • Percent error compares a measurement with a known true value. The true value goes on the bottom.
  • Percent difference compares two measurements when neither is "correct". It divides by their average: |a − b| ÷ ((a + b) ÷ 2) × 100.
  • Percent change compares an old value with a new one, dividing by the old value. For price rises and growth, use the percentage calculator.

If your lab sheet says "compare with the accepted value", it wants percent error.

Sources of error to discuss in a lab report

When the percent error calculator gives a number, the next step is explaining it. Common sources:

  • Instrument precision: a ruler marked in millimetres can't measure tenths of a millimetre.
  • Reaction time: starting and stopping a stopwatch adds around 0.1 to 0.3 seconds.
  • Calibration: a scale or thermometer that reads consistently high or low.
  • Environment: air resistance, friction, heat loss, temperature changes.
  • Method: parallax when reading a scale at an angle, or a sample that wasn't pure.

Repeating measurements and averaging them reduces random error; the standard deviation calculator shows how much your repeats vary. It doesn't fix systematic error, which is why comparing with a true value matters.

Using percent error outside the lab

  • Business forecasts: compare forecast sales with actual sales to see how good your forecasting is. A forecast of 48,000 against actual sales of 50,000 is a 4% error.
  • Quality control: check a filling machine or scale against a certified weight.
  • Budgets: compare estimated and actual project costs.
  • Navigation and fitness trackers: compare a GPS distance with a measured course.
  • Cooking and baking: check a kitchen scale against a known weight.

Tips

  • Put the true value in the right box. Swapping them changes the answer, because the formula divides by the true value.
  • Keep the units the same. Convert first if one value is in grams and the other in kilograms.
  • Don't round too early. Use full values in the percent error calculator and round the final answer.
  • Report the sign if your teacher or report asks whether results were high or low.

Privacy and accuracy

Your numbers stay in your browser; nothing is uploaded or stored. The percent error calculator uses the standard formula with no rounding until the result is displayed, and no AI is involved, so the same inputs always give the same answer. Students, teachers, lab technicians and analysts use it on any device, free.

Accuracy vs precision

Percent error measures accuracy: how close a result is to the true value. Precision is different: how close repeated measurements are to each other.

  • A scale that always reads 502 g for a 500 g weight is precise but not accurate (a 0.4% error every time).
  • Measurements of 480, 520, 495 and 505 g average 500 g, which is accurate on average but not precise.

Good experiments need both. Use the percent error calculator for accuracy, and the standard deviation calculator for the spread of repeated measurements.

Percent error in a lab report

A clear results section usually includes:

  1. The measured value, with units and the right significant figures.
  2. The accepted value and its source.
  3. The percent error, often rounded to two or three significant figures.
  4. Whether the result was high or low (the signed error).
  5. The most likely sources of error, and how to reduce them.

The percent error calculator gives you items 3 and 4 in one step.

Quick reference

  • Absolute error: |measured − true|, in the original units.
  • Relative error: absolute error ÷ |true value|, as a decimal.
  • Percent error: relative error × 100.
  • Signed percent error: keeps the sign; negative means the measurement was low.
  • Percent difference: compares two measurements with no true value, dividing by their average.
  • Systematic error: pushes every result the same way (a miscalibrated scale).
  • Random error: scatters results both ways (reaction time, reading a scale).

The percent error calculator reports the first four, so you can quote whichever your teacher or report needs.

When the true value is uncertain

Sometimes the "accepted" value is itself a measurement with its own uncertainty. In that case, report your result with its uncertainty and say whether the two overlap, rather than relying on percent error alone. For everyday lab work, the percent error calculator is the standard measure.

A worked example

A physics class measures the acceleration due to gravity with a pendulum. One group's average result is 9.6 m/s². The accepted value is 9.81 m/s². They enter both into the percent error calculator.

The percent error is 2.14%, the signed percent error is −2.14% and the absolute error is 0.21 m/s². In their report they write that the result is within 2.2% of the accepted value, which is good for school equipment, and that it came out low. Looking for something that would push g down, they find they measured the string only to the top of the bob, not to its centre. Since g = 4π²L ÷ T², a length that's too short gives a value of g that's too low, so they note it as a systematic error to fix next time.

Another group measures a 2.5 cm reference block as 2.48 cm with a ruler: a percent error of 0.8%, low, as expected for a ruler marked in millimetres.

Need more customers from Google?

This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. That is the whole job of DeepRit: a PPC-only agency that sets up and runs Google Ads accounts so every click is accounted for. You keep full ownership of your account, get a written report every week, and can stop at any time. See our pricing or ask for a free audit.

Frequently asked questions

How do I calculate percent error?

Subtract the true value from the measured value, ignore the sign, divide by the true value and multiply by 100. The percent error calculator does it in one step.

Can percent error be negative?

Percent error itself is always positive. The signed percent error can be negative, which means your measurement was below the true value.

Can percent error be over 100%?

Yes. If you measure 25 when the true value is 10, the percent error is 150%.

What if the true value is zero?

Percent error can't be calculated, because it would divide by zero. Report the absolute error instead.

What's a good percent error for a lab?

In school labs, under 5% is usually good. It depends on the equipment and the experiment.

Is the percent error calculator free?

Yes. It's free and needs no sign-up.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep