Free R-value calculator. Add up the R-values of wall or roof layers to get the total R-value and U-factor, and the heat lost through an area.

U-factor
0
In the other system
0
Heat loss
0

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the R-value calculator

  1. List the R-value of each layer in the wall, roof or floor, separated by commas. Include air films, boards, insulation and finishes.
  2. Choose the units: US R-values (ft²·°F·h/BTU) or metric RSI values (m²·K/W).
  3. Enter the area in square feet or square metres.
  4. Enter the temperature difference between inside and outside, in °F or °C.

The R-value calculator shows the total R-value, the U-factor (the inverse of R), the same R-value in the other unit system, and the rate of heat loss through the area.

What is an R-value?

An R-value measures thermal resistance: how well a material or assembly resists the flow of heat. The higher the R-value, the better the insulation. Insulation products are sold by their R-value, such as R-13 or R-38 fibreglass batts in the US, or by their thermal resistance in m²·K/W elsewhere.

For layers in series, such as the layers of a wall, R-values simply add up:

Total R = R₁ + R₂ + R₃ + …

With the default values, an inside air film of 0.68, an R-13 insulation layer, sheathing of 0.45 and an outside air film of 0.17, the total is R-14.3.

US and metric R-values

There are two unit systems, and mixing them up is a common error:

  • US R-value: ft²·°F·h/BTU. Typical insulation products range from about R-3 to R-60.
  • Metric RSI value: m²·K/W. Typical products range from about 0.5 to 10.

1 RSI = 5.678 US R-value units, so R-13 is about RSI 2.29, and RSI 2.5 is about R-14.2. The R-value calculator converts between them automatically.

U-factor and heat loss

The U-factor, or U-value, is the inverse of the total R-value:

U = 1 ÷ R

It measures how much heat passes through each unit of area for each degree of temperature difference. Lower U-values mean better insulation. U-values are used for windows and doors, and in building regulations in many countries.

The rate of heat flow through an area is:

Heat loss = area × temperature difference ÷ R = area × temperature difference × U

For 500 square feet of the default wall with a 40 °F difference, the heat loss is 500 × 40 ÷ 14.3 ≈ 1,399 BTU per hour. In metric units, the result is in watts.

Air films

Still air next to a surface adds a small amount of resistance. Insulation calculations usually include an inside air film and an outside air film. Typical US values used in many tables are about R-0.68 for an inside wall surface and about R-0.17 for an outside surface in winter wind, with different values for ceilings and floors. They're small compared with insulation, but they're part of a complete calculation.

A worked example: an attic

An attic ceiling has drywall (R-0.45), R-38 blown insulation, and inside and outside air films of R-0.61 each.

  1. Total R: 0.61 + 38 + 0.45 + 0.61 = R-39.67.
  2. U-factor: 1 ÷ 39.67 ≈ 0.0252.
  3. Heat loss for 1,000 sq ft at a 30 °F difference: 1,000 × 30 ÷ 39.67 ≈ 756 BTU per hour.
  4. Metric: about RSI 6.99.

Enter "0.61, 38, 0.45, 0.61" in the R-value calculator to check.

A metric example

A wall has an internal surface resistance of 0.13, insulation of RSI 2.5, a board layer of 0.06 and an external surface resistance of 0.04, all in m²·K/W.

  1. Total RSI: 0.13 + 2.5 + 0.06 + 0.04 = 2.73.
  2. U-value: 1 ÷ 2.73 ≈ 0.366 W/m²·K.
  3. Heat loss through 50 m² at a 20 °C difference: 50 × 20 × 0.366 ≈ 366 watts.

Choose metric units, enter "0.13, 2.5, 0.06, 0.04", 50 and 20 to check.

Thermal bridging

The R-value calculator adds layers in series, which assumes heat flows evenly through the whole area. Real walls have studs, joists and other framing that conduct heat much better than insulation. Wood has an R-value of roughly 1 per inch, compared with about 3 to 4 for many fibreglass and mineral wool products. Heat takes the easier path through the framing, so a wall with R-13 batts between studs performs noticeably worse overall than R-13. This is called thermal bridging. Continuous insulation boards over the outside of the framing reduce it. For a more realistic figure, calculate the R-value through the framing and through the insulation separately, then combine them weighted by area, or use the whole-wall values published by building science organisations.

Who uses an R-value calculator

Homeowners use it to compare insulation upgrades and understand energy bills. Builders and contractors use it to check that walls and roofs meet code. Energy auditors use it to estimate heat loss and savings. Architects and engineers use it in early design. Insulation installers use it to explain options to customers.

Get the next job from Google

Homeowners search Google when something breaks. Search ads put a local trade business at the top of those searches. DeepRit manages Google Ads for small and mid-size businesses, and only Google Ads. We check your account before we ever get on a call, then fix the structure, the keywords, the tracking and the ads, with month-to-month terms and no long contract. Book a free audit call.

Diminishing returns

Because heat loss is proportional to 1 ÷ R, each extra unit of insulation saves less than the one before. Going from R-11 to R-22 halves the heat loss through that area; going from R-22 to R-33 cuts it by only another third of what remains. That's why the first few inches of insulation in an uninsulated attic save far more energy than topping up an already well-insulated one. Use the R-value calculator to compare heat loss before and after an upgrade, and weigh the saving against the cost.

Air sealing matters too

R-values describe conduction through materials. They don't account for air leaking through gaps, cracks and openings, which can carry a large share of a home's heat loss. Insulation works best when the building is also air-sealed: gaps around pipes, wiring, loft hatches and windows are sealed before insulation is added. An energy audit with a blower-door test can measure how leaky a building is.

Moisture and compression

Insulation must be installed properly to deliver its rated R-value. Compressing a batt into a cavity that's too shallow reduces its R-value, and wet insulation performs much worse than dry. Gaps and voids also allow heat to bypass the insulation. Follow the manufacturer's instructions and local codes, including any requirements for vapour control layers in your climate.

Common mistakes

  • Mixing US R-values and metric RSI values.
  • Ignoring thermal bridging through studs and joists.
  • Adding R-values of layers side by side instead of in series. Only layers that heat passes through one after another add directly.
  • Assuming compressed or wet insulation still has its rated R-value.

R-value per inch of common materials

Different insulation materials give different R-values for the same thickness. Typical figures quoted in building guides, in US units per inch of thickness, are roughly:

  • Fibreglass and mineral wool batts: about R-3 to R-4.3 per inch.
  • Blown cellulose: about R-3.2 to R-3.8 per inch.
  • Expanded polystyrene (EPS) board: about R-3.6 to R-4.2 per inch.
  • Extruded polystyrene (XPS) board: about R-5 per inch.
  • Polyisocyanurate board: about R-6 per inch or more when new.
  • Closed-cell spray foam: about R-6 to R-7 per inch.
  • Softwood lumber: about R-1.25 per inch.

Product labels give the tested R-value for a specific thickness, which is the figure to enter in the R-value calculator. Multiply a per-inch value by the thickness to estimate a layer's R-value when you don't have a label.

Estimating savings from an upgrade

To estimate how much an upgrade could save, run the R-value calculator twice: once for the existing assembly and once with the added insulation, keeping the area and temperature difference the same. The difference in heat loss, multiplied by the number of hours in the heating season and adjusted for your heating system's efficiency and fuel cost, gives a rough annual saving. Energy auditors use more detailed methods based on local climate data, but this comparison shows clearly whether an upgrade is likely to be worthwhile.

Building codes and energy programmes set minimum insulation levels that depend on the climate zone and the part of the building. Colder climates require higher R-values, especially for attics. Check your local code or national energy guidance for the levels that apply to you.

Sources and further reading

Frequently asked questions

How do I calculate the total R-value of a wall?

Add the R-values of all the layers heat passes through, including air films.

What is the difference between R-value and U-value?

U-value is 1 ÷ R. Higher R-values and lower U-values mean better insulation.

How do I convert US R-value to metric RSI?

Divide by 5.678. R-13 is about RSI 2.29.

Why is my wall's real R-value lower than the insulation's?

Framing conducts heat more easily than insulation, a problem called thermal bridging.

How much heat does a wall lose?

Area × temperature difference ÷ total R-value, in BTU per hour (US) or watts (metric).

Is the R-value calculator free?

Yes. It's free, needs no sign-up, and works in your browser.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep