Flow Rate Converter

A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call

Free flow rate converter. Convert litres per minute, US and UK gallons per minute, cubic feet per minute (CFM), m³/h and more for pumps, pipes and air.

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the flow rate converter

  1. Enter a flow rate, such as 10 or 5.5.
  2. Choose its unit: litres per second, minute or hour; cubic metres per second or hour; US gallons per minute (GPM) or hour; UK gallons per minute; cubic feet per minute (CFM); or cubic feet per second.
  3. Read the table. The flow rate converter shows the same flow in every other unit, with a Copy button next to each.

It works instantly in your browser, with no limit on the size of the numbers.

What flow rate is

Volumetric flow rate is the volume of fluid (liquid or gas) passing a point per unit of time:

Flow rate = volume ÷ time

It's how pump output, tap and shower flow, pipe capacity, ventilation, and river and irrigation flows are measured. The SI unit is the cubic metre per second (m³/s), but litres per minute, gallons per minute and cubic feet per minute are far more common in practice.

Flow rate conversion factors

Unit In litres per minute
1 litre per second (L/s) 60 L/min
1 litre per hour (L/h) 0.016667 L/min
1 cubic metre per hour (m³/h) 16.6667 L/min
1 cubic metre per second (m³/s) 60,000 L/min
1 US gallon per minute (GPM) 3.785412 L/min
1 US gallon per hour 0.063090 L/min
1 UK gallon per minute 4.54609 L/min
1 cubic foot per minute (CFM) 28.316847 L/min
1 cubic foot per second 1,699.0108 L/min

Some handy equivalents:

  • 10 L/min = 0.6 m³/h = 2.642 US GPM = 2.200 UK GPM = 0.353 CFM.
  • 5 US GPM = 18.93 L/min = 1.136 m³/h = 300 US gallons per hour.
  • 1 m³/h = 16.67 L/min = 4.403 US GPM.
  • 100 CFM = 2,831.7 L/min = 169.9 m³/h.

US gallons versus UK gallons

Gallons are a common source of mistakes:

  • US gallon: 3.785411784 litres (231 cubic inches).
  • UK (imperial) gallon: 4.54609 litres.

A UK gallon is about 20% larger, so the same flow is a smaller number in UK GPM. Pump and fixture specifications from the US use US gallons; older UK specs may use imperial. The flow rate converter shows both, clearly labelled. For converting volumes rather than flows, use the volume converter.

Where flow rates matter

Plumbing. Showers, taps and appliances have flow rates. Many water-efficiency standards cap shower heads at around 9 L/min or lower, and US federal rules cap them at 2.5 GPM (9.46 L/min); some states set lower limits. Measure your own shower by timing how long it takes to fill a bucket.

Pumps. Pump curves show flow (in L/min, m³/h or GPM) against pressure or head. Choosing a pump means matching the flow you need at the pressure your system requires. The pressure converter converts between bar, psi and other pressure units.

Filling and emptying. Time to fill = volume ÷ flow rate. A 1,000-litre tank at 20 L/min takes 50 minutes. The volume calculator works out the volume of tanks, pools and ponds.

Ventilation and HVAC. Fans and air handling are rated in CFM (US) or m³/h and L/s (metric). Room ventilation is often specified in air changes per hour: room volume × air changes ÷ 60 = flow in volume per minute.

Irrigation and gardening. Sprinklers and drip systems are sized by flow rate, often in L/h for drippers and L/min or GPM for zones.

Industry and engineering. Process flows, cooling water, compressed air and fuel systems.

Flow rate, velocity and pipe size

Flow rate is linked to how fast the fluid moves and the size of the pipe:

Flow rate = velocity × cross-sectional area

For a round pipe, the area is π × (diameter ÷ 2)². Pushing the same flow through a smaller pipe makes it move faster, which increases friction losses and noise. Designers keep water velocities within recommended limits (often around 1–3 m/s in buildings) by choosing pipe sizes to suit the flow. The speed converter handles velocity units.

Mass flow versus volume flow

This converter handles volumetric flow (volume per time). Mass flow (kg/s or lb/h) depends on the fluid's density. For water, 1 litre weighs about 1 kg, so 10 L/min of water is about 10 kg/min. For gases, density changes a lot with pressure and temperature, so check whether a spec means actual or standard flow.

Measuring flow rate yourself

You can measure the flow rate of a tap, shower or hose with a bucket and a timer:

  1. Use a container of known volume, such as a 10-litre bucket.
  2. Turn the water fully on and time how long it takes to fill.
  3. Divide the volume by the time.

If a 10-litre bucket fills in 50 seconds, the flow rate is 10 ÷ 50 = 0.2 L/s, or 12 L/min. Enter 12 L/min in the flow rate converter to see it in GPM and other units. Repeat the test a couple of times and average the results.

Flow rate and water bills

Flow rate makes water use easy to estimate. A shower running at 12 L/min for 8 minutes uses 96 litres. Switching to a 7 L/min water-saving shower head cuts that to 56 litres, saving 40 litres per shower. Over a year of daily showers, that's about 14,600 litres, which also saves the energy used to heat the water.

Flow rate units by industry

  • Domestic plumbing and appliances: L/min in metric countries, GPM in the US.
  • Pumps: m³/h and L/min, or GPM in the US.
  • Ventilation and air conditioning: L/s or m³/h in metric countries, CFM in the US.
  • Rivers and large water systems: m³/s, or cubic feet per second in the US.
  • Medical and laboratory equipment: mL/min and mL/h.

Specifications from different countries can use different units for the same thing, which is exactly where a flow rate converter helps avoid ordering the wrong pump or fan.

Flow rate for heating and cooling systems

Heating and cooling systems move water or air at a set flow rate to carry heat. For water-based heating, the heat carried depends on the flow rate and the temperature difference between the flow and return pipes: roughly, 1 L/min of water cooling by 10°C carries about 0.7 kW of heat. Installers use this to size pumps and pipes for radiators, underfloor heating and heat pumps. If a specification gives flow in GPM or m³/h, convert it to L/min or L/s with the flow rate converter so it matches the units in your calculations.

Flow rate and pipe size in practice

Doubling a pipe's diameter gives four times the cross-sectional area, so the same flow moves at a quarter of the speed. That's why larger pipes are used for long runs and high flows: slower water means less friction, less pressure loss and less noise. If you know the flow rate and the pipe's internal diameter, divide the flow by the area to estimate the velocity, keeping the units consistent.

Rounding flow rates

Pump and fixture ratings are usually given to two or three significant figures, so round converted values similarly: 18.93 L/min is fine to quote as about 19 L/min.

A worked example

A plumber is replacing a pump for a garden irrigation system. The old pump's datasheet, from a US manufacturer, says it delivers 5 GPM. The new pumps she's comparing are rated in L/min and m³/h.

She enters 5 and chooses US gallons per minute in the flow rate converter:

  • 18.93 L/min.
  • 1.136 m³/h.
  • 300 US gallons per hour.
  • 4.16 UK gallons per minute.

She picks a pump rated at 20 L/min at the system's pressure. To check filling time for the 1,000-litre storage tank, she works out 1,000 ÷ 20 = 50 minutes.

Need more customers from Google?

This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit is a Google Ads agency that does PPC and nothing else: we build the campaigns, block the searches that waste money, write the ads, set up conversion tracking and send you a short report every week. Request a free PPC audit and we will show you, in dollars, what we would fix first.

Frequently asked questions

How do I convert GPM to L/min?

Multiply US gallons per minute by 3.785412. 5 GPM is 18.93 L/min. For UK gallons, multiply by 4.54609.

How do I convert L/min to m³/h?

Multiply by 0.06. 10 L/min is 0.6 m³/h.

What is CFM?

Cubic feet per minute, a common unit for air flow. 1 CFM is about 28.32 L/min or 1.699 m³/h.

Are US and UK gallons the same?

No. A UK gallon is 4.54609 litres and a US gallon is 3.785 litres.

How do I work out how long a tank takes to fill?

Divide the tank's volume by the flow rate, in matching units.

Is the flow rate converter free?

Yes. It's free, needs no sign-up, and works in your browser.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep