Dilution Calculator (C1V1 = C2V2)

A free tool by DeepRit, a Google Ads agency that does PPC and nothing else. We build and run Google Ads accounts so every click is accounted for. Book a free audit call

Free dilution calculator using C1V1 = C2V2. Find the stock volume, final volume or concentration, plus how much solvent to add. Works with any units.

Use the same units for both concentrations and for both volumes.

Solvent to add
0
Dilution factor
0

Free, no sign-up. Runs in your browser: nothing you type is uploaded or saved.

How to use the dilution calculator

  1. Choose what to solve for: V1 (the volume of stock), C1 (the stock concentration), V2 (the final volume) or C2 (the final concentration).
  2. Enter the other three values. Use the same units for both concentrations, and the same units for both volumes.
  3. Read the result, along with how much solvent to add and the dilution factor.

The dilution calculator works with any concentration units, such as mol/L, mg/mL, percent or parts per million, and any volume units, such as mL, L or µL, as long as each pair matches.

The dilution equation

When you dilute a solution, you add solvent but no extra solute. The amount of solute stays the same, so:

C1 × V1 = C2 × V2

  • C1 is the concentration of the stock solution.
  • V1 is the volume of stock you take.
  • C2 is the concentration you want.
  • V2 is the final volume after dilution.

Rearranging gives each value:

  • V1 = C2 × V2 ÷ C1
  • C1 = C2 × V2 ÷ V1
  • V2 = C1 × V1 ÷ C2
  • C2 = C1 × V1 ÷ V2

With the default figures, to make 500 mL of 1 M solution from a 12 M stock, V1 = 1 × 500 ÷ 12 ≈ 41.67 mL. You'd take 41.67 mL of stock and add solvent to a total of 500 mL, which means adding about 458.33 mL.

Dilution factor

The dilution factor is how many times weaker the final solution is than the stock:

Dilution factor = C1 ÷ C2 = V2 ÷ V1

Diluting 12 M to 1 M is a 12-fold dilution, sometimes written 1:12. Biologists often describe dilutions this way, for example "dilute the antibody 1:1000". A 1:1000 dilution means 1 part stock in a total of 1,000 parts, so 1 µL of stock made up to 1 mL. Be careful: some people use "1:1000" to mean 1 part stock plus 1,000 parts diluent, which is slightly different. When precision matters, state the final volume explicitly.

A worked example: diluting to a percentage

You have 70% isopropyl alcohol and want 1 litre of 50% solution.

  1. Solve for V1: 50 × 1,000 ÷ 70 ≈ 714.3 mL.
  2. Add water: 1,000 − 714.3 = 285.7 mL.

So mix about 714 mL of 70% alcohol with water to a total of 1 litre. Because alcohol and water shrink slightly when mixed, it's more accurate to make up to the final volume than to add exactly 285.7 mL. Enter C1 = 70, C2 = 50 and V2 = 1,000 in the dilution calculator, solving for V1, to check.

Serial dilutions

When you need a very large dilution, such as 1 in 1,000,000, a single step would require measuring an impractically tiny volume. Instead, laboratories use serial dilutions: several smaller dilutions in a row. Six tenfold dilutions, each taking 100 µL into 900 µL of diluent, give a total dilution of 10⁶. The total dilution factor is the product of the individual factors. Serial dilutions are used to count bacteria, prepare standard curves and titrate antibodies. You can use the dilution calculator for each step separately.

Diluting acids safely

When diluting concentrated acids, especially sulfuric acid, always add acid to water, slowly, never water to acid. Mixing releases a lot of heat, and adding water to concentrated acid can make it boil and spatter. Wear eye protection and gloves, work in a fume hood if required, and follow your laboratory's safety procedures. The dilution calculator gives the volumes; safe technique is up to you.

Who uses a dilution calculator

Chemistry and biology students use it for practical classes. Laboratory staff use it daily to prepare working solutions from stocks. Medical laboratory scientists use it for reagents and sample dilutions. Pharmacists and nurses use the same principle to dilute medicines, following their own protocols. Gardeners and cleaners use it to dilute concentrated fertilisers, disinfectants and cleaning products to the strength on the label.

Need more customers from Google?

This tool is free and runs in your browser. If your business also needs more leads or sales, Google Ads is where people search with their wallet out. DeepRit is a Google Ads agency that does PPC and nothing else: we build the campaigns, block the searches that waste money, write the ads, set up conversion tracking and send you a short report every week. Request a free PPC audit and we will show you, in dollars, what we would fix first.

Diluting household products

The same equation applies to concentrated products at home. If a disinfectant concentrate is 10% and the label says to use it at 0.5%, the dilution factor is 20, so mix 1 part concentrate with water to make 20 parts in total: 50 mL of concentrate made up to 1 litre. Always follow the manufacturer's dilution instructions and safety warnings, which may specify things the equation doesn't, such as contact times and which products must never be mixed.

Units must match

The equation only works when C1 and C2 are in the same units, and V1 and V2 are in the same units. You can mix concentration units with volume units freely, for example mg/mL with litres, but you can't use mol/L for one concentration and mmol/L for the other without converting. If your stock is labelled in different units from your target, convert one of them first. The molarity calculator helps convert between mass and molar concentration.

When C1V1 = C2V2 doesn't apply

The equation assumes that diluting doesn't change the amount of solute, which is true for simple dilutions. It doesn't apply when the solute reacts with the diluent, when you mix two solutions of the same substance at different concentrations, or when volumes change significantly on mixing, as with some alcohol and acid mixtures. For mixing two different concentrations, use C1V1 + C2V2 = C3V3, which adds the moles from both.

Common mistakes

  • Mixing units between C1 and C2 or between V1 and V2.
  • Adding V2 of solvent instead of making up to a total of V2.
  • Confusing dilution ratios such as 1:10 (1 part in 10 total) with 1 part plus 10 parts.
  • Adding water to concentrated acid. Always add acid to water.

Dilutions in microbiology and cell culture

Microbiologists use dilutions to count bacteria. A sample is serially diluted, small volumes are spread on agar plates, and colonies are counted on the plate with a countable number, usually around 30 to 300. The number of colonies multiplied by the total dilution factor, divided by the volume plated, gives the concentration in the original sample. For example, 150 colonies from 0.1 mL of a 10⁻⁵ dilution means 150 × 10⁵ ÷ 0.1 = 1.5 × 10⁸ colony-forming units per mL. Cell culture follows the same logic when seeding cells at a target density: the stock cell count is C1, the density you want is C2 and the final volume is V2, and the dilution calculator gives the volume of cell suspension to add.

Diluting in the kitchen and garden

Dilution maths isn't only for laboratories. Concentrated fruit squash, liquid plant food, weedkiller and pool chemicals all come with dilution instructions, and the dilution calculator turns them into exact amounts. If a liquid plant food should be used at 5 mL per litre and you have a 9-litre watering can, use 45 mL. If a cleaner should be diluted to 2% and the concentrate is 20%, the dilution factor is 10, so 100 mL of concentrate makes a litre of solution. Always follow the label for safety-critical products, because some require exact strengths to work properly or to stay safe.

Accuracy in practice

The result is only as accurate as your measurements. Graduated cylinders are typically accurate to about 1% of their capacity, while volumetric pipettes and flasks are far more precise. For small volumes, use a calibrated micropipette and a tip suited to the volume. When the volume of stock is very small compared with the final volume, a two-step dilution with larger, easier-to-measure volumes is usually more accurate than a single step. The dilution calculator can plan each step.

Checking your answer

A quick sense check helps catch mistakes: the stock volume V1 must always be smaller than the final volume V2, and the final concentration C2 must be smaller than the stock concentration C1. If the dilution calculator gives a V1 larger than V2, the target concentration is higher than the stock, which isn't possible by dilution; the calculator warns you if that happens.

Sources and further reading

Frequently asked questions

What is the dilution formula?

C1 × V1 = C2 × V2: stock concentration × stock volume = final concentration × final volume.

How much stock do I need?

V1 = C2 × V2 ÷ C1.

How much water do I add?

The final volume minus the stock volume, though making up to the final volume is more accurate.

What is a dilution factor?

How many times weaker the final solution is: C1 ÷ C2.

Can I use percentages?

Yes, as long as both concentrations are percentages of the same kind.

Is the dilution calculator free?

Yes. It's free, needs no sign-up, and works in your browser.

Free PPC audit

See where your ad budget leaks.

We look at your Google Ads account before the call, then walk you through what we'd fix first, in dollars. No obligation, no hard sell.

Book a free audit call 30-minute call · Free · The audit is yours to keep